English
Language : 

10-F106NIA100SA-M135F Datasheet, PDF (22/27 Pages) Vincotech – Neutral-point-Clamped inverter
10-xx06NIA100SA-M135Fxx
Switching Definitions BUCK IGBT
Figure 9
Output inverter FRED
Turn-on Switching Waveforms & definition of tQrr
(tQrr = integrating time for Qrr)
150
%
Id
Qrr
100
tQrr
50
0
-50
-100
-150
3,1
3,2
3,3
3,4
3,5
Id (100%) =
Qrr (100%) =
tQrr =
100
A
9,36
µC
0,33
µs
3,6
3,7
time(us)
Figure 10
Output inverter FRED
Turn-on Switching Waveforms & definition of tErec
(tErec= integrating time for Erec)
125
%
100
Erec
75
tErec
50
Prec
25
0
-25
3,1
3,2
Prec (100%) =
Erec (100%) =
tErec =
3,3
34,85
2,24
0,33
3,4
kW
mJ
µs
3,5 time(us) 3,6
14,06205 1
84364100,400 1
Measurement circuit
Figure 11
BUCK stage switching measurement circuit
Copyright by Vincotech
22
Revision: 3