English
Language : 

10-F106NIA100SA-M135F Datasheet, PDF (1/27 Pages) Vincotech – Neutral-point-Clamped inverter
10-xx06NIA100SA-M135Fxx
flowNPC 1
Features
● Neutral-point-Clamped inverter
● Compact flow1 housing
● Low Inductance Layout
Target Applications
● UPS
● Motor Drive
● Solar inverters
Types
● 10-F106NIA100SA-M135F
● 10-P106NIA100SA-M135FY
● 10-FY06NIA100SA-M135F08
600V/100A
flow1 housing
17mm height
Schematic
12mm height
Tj=25°C, unless otherwise specified
Parameter
Buck IGBT
Collector-emitter break down voltage
DC collector current
Pulsed collector current
Power dissipation per IGBT
Gate-emitter peak voltage
Short circuit ratings
Maximum Junction Temperature
Turn off safe operating area
Buck Diode
Peak Repetitive Reverse Voltage
DC forward current
Repetitive peak forward current
Power dissipation per Diode
Maximum Junction Temperature
Maximum Ratings
Symbol
Condition
Value
Unit
VCE
IC
ICpulse
Ptot
VGE
tSC
VCC
Tjmax
Tj=Tjmax
tp limited by Tjmax
Tj=Tjmax
Tj≤150°C
VGE=15V
Tj≤150°C
VCE<=VCES
VRRM
IF
IFRM
Ptot
Tjmax
Tj=25°C
Tj=Tjmax
tp limited by Tjmax
Tj=Tjmax
Th=80°C
Tc=80°C
Th=80°C
Tc=80°C
600
V
84
A
110
300
A
136
W
206
±20
V
6
µs
360
V
175
°C
200
A
600
V
Th=80°C
Tc=80°C
53
A
72
Tc=100°C
300
A
Th=80°C
Tc=80°C
70
W
106
175
°C
Copyright by Vincotech
1
Revision: 3