English
Language : 

10-F106NIA100SA-M135F Datasheet, PDF (20/27 Pages) Vincotech – Neutral-point-Clamped inverter
10-xx06NIA100SA-M135Fxx
Switching Definitions BUCK IGBT
General conditions
Tj
Rgon
Rgoff
= 150 °C
= 8Ω
= 8Ω
Figure 1
Output inverter IGBT
Turn-off Switching Waveforms & definition of tdoff, tEoff
(tEoff = integrating time for Eoff)
125
%
tdoff
VCE
100
75
VGE 90%
VGE
VCE 90%
IC
50
tEoff
25
0
IC 1%
Figure 2
Output inverter IGBT
Turn-on Switching Waveforms & definition of tdon, tEon
(tEon = integrating time for Eon)
250
%
IC
200
150
100
50
0
VCE
tdon
VGE10%
VGE
IC 10%
tEon
VCE 3%
-25
-0,2
VGE (0%) =
VGE (100%) =
VC (100%) =
IC (100%) =
tdoff =
tEoff =
0
0,2
-15
V
15
V
350
V
100
A
0,30
µs
0,55
µs
0,4
0,6
time (us)
-50
2,9
3
3,1
3,2
3,3
3,4
3,5
time(us)
VGE (0%) =
VGE (100%) =
VC (100%) =
IC (100%) =
tdon =
tEon =
-15
V
15
V
350
V
100
A
0,19
µs
0,39
µs
Figure 3
Turn-off Switching Waveforms & definition of tf
125
%
IC
fitted
VCE
100
IC 90%
Output inverter IGBT
75
IC 60%
50
IC 40%
25
IC10%
0
tf
Figure 4
Turn-on Switching Waveforms & definition of tr
250
%
IC
200
Output inverter IGBT
150
VCE
100
50
0
IC 90%
tr
IC 10%
-25
0,1
VC (100%) =
IC (100%) =
tf =
0,2
0,3
350
V
100
A
0,12
µs
0,4
time (us) 0,5
-50
3,1
VC (100%) =
IC (100%) =
tr =
3,2
3,3
350
V
100
A
0,03
µs
3,4
3,5
time(us)
Copyright by Vincotech
20
Revision: 3