English
Language : 

PI352X-00 Datasheet, PDF (7/34 Pages) Vicor Corporation – 30VIN to 60VIN Cool-Power ZVS Buck Regulator
PI352x-00 Common Electrical Characteristics
Specifications apply for -40°C < TINT < 120°C, VIN = 48V, EN = High, unless otherwise noted.
Parameter
Symbol
Conditions
PI352x-00
Min
Typ
Max
Unit
Open Loop Gain
Small Signal Gain-bandwidth
Input Offset
Common Mode Input Range
Differential Mode Input Range
Input Bias Current
Output Current
Maximum VOUT
Minimum VOUT
Capacitive Load Range for Stability
Slew Rate
Differential Amp
IVDIFF = -1mA
IVDIFF = -1mA
96
120
140
dB
5
7
12
MHz
0.5
1
mV
-0.1
2.5
V
2
V
-1
1
µA
-1
1
mA
4.85
V
20
mV
0
50
pF
11
V/µs
VOUT Rising Threshold
VOUT Falling Threshold
PWRGD Output Low
VPG_HI%
VPG_LO%
VPG_SAT
Sink = 4mA
PWRGD
78
84
90 % VOUT_DC
75
81
87 % VOUT_DC
0.4
V
Voltage Setpoint
External Loading
VVDR
IVDR
VDR
VIN_DC > 10V
See Application Description for details
4.9
5.05
5.2
V
0
2
mA
High Threshold
Low Threshold
Threshold Hysteresis
Pull-Up Voltage level for
source current
Pull-Up Current
VEN_HI
VEN_LO
VEN_HYS
VEN_PU
IEN_PU_POS
Enable
0.9
1.0
1.1
V
0.7
0.8
0.9
V
100
200
300
mV
2
V
50
µA
Reliability
MTBF
MIL-HDBK-217, 25ºC, Ground Benign: GB
Telcordia SR-332, 25ºC, Ground Benign: GB
12.6
MHrs
96.9
MHrs
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI352x evaluation board with 2.5 x 4”
dimensions and 4 layer, 2oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control.
Output voltage is determined by an external feedback divider ratio.
[3] Output current capability may be limited and other performance may vary from noted electrical characteristics when VOUT is not set to nominal.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.
Cool-Power® ZVS Switching Regulators
Page 7 of 34
Rev 1.3
06/2017
vicorpower.com
800 927.9474