PI3311-x0-LGIZ (1.0VOUT) Electrical Characteristics (Cont.)
Unless otherwise specified: -40°C < TJ < 125°C, VIN = 24V, L1 = 125nH [1]
Parameter
Symbol
Conditions
PI33xx-x0
Min
Typ
Max
Unit
Switching Frequency
Fault Restart Delay
fS
[6]
tFR_DLY
Timing
500
kHz
30
ms
Synchronization Frequency Range
SYNCI Threshold
∆fSYNCI
VSYNCI
Sync In (SYNCI)
Relative to set switching frequency [3]
50
110
%
2.5
V
SYNCO High
SYNCO Low
SYNCO Rise Time
SYNCO Fall Time
VSYNCO_HI
VSYNCO_LO
tSYNCO_RT
tSYNCO_FT
Sync Out (SYNCO)
Source 1mA
Sink 1mA
20pF load
20pF load
4.5
V
0.5
V
10
ns
10
ns
TRK Active Input Range
TRK Max Output Voltage
TRK Disable Threshold
Charge Current (Soft – Start)
Discharge Current (Fault)
Soft-Start Time
Soft Start And Tracking
VTRK
Internal reference tracking range
VTRK_OV
ITRK
ITRK_DIS
tSS
VTRK = 0.5V
CTRK = 0µF
0
1.04
V
1.2
V
20
40
60
mV
70
50
30
μA
6.8
mA
2.2
ms
Enable
High Threshold
Low Threshold
Threshold Hysteresis
Enable Pull-Up Voltage
(Floating)
Enable Pull-Down Voltage
(Floating)
VEN_HI
VEN_LO
VEN_HYS
VEN_PU
VEN_PD
With positive logic EN polarity
With negative logic EN polarity
0.9
1
1.1
V
0.7
0.8
0.9
V
100
200
300
mV
2
V
0
V
Source Current
IEN_SO
With positive logic EN polarity
50
μA
Sink Current
IEN_SK
With negative logic EN polarity
50
μA
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI33xx-x0 evaluation board with 3x4”
dimensions and 4 layer, 2oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control.
[3] Output current capability may be limited and other performance may vary from electrical characteristics when switching frequency or VOUT is modified.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.