English
Language : 

PI3303-00-EVAL1 Datasheet, PDF (12/42 Pages) Vicor Corporation – Cool-Power® ZVS Switching Regulators
PI3312-x0-LGIZ (2.5VOUT) Electrical Characteristics
Unless otherwise specified: -40°C < TJ < 125°C, VIN = 24V, L1 = 200nH [1]
Parameter
Symbol
Conditions
PI33xx-x0
Min
Typ
Max
Unit
Input Voltage
Input Current
Input Current At Output Short (fault
condition duty cycle)
Input Quiescent Current
Input Voltage Slew Rate
VIN_DC
IIN_DC
IIN_Short
IQ_VIN
VIN_SR
Input Specifications
[7]
VIN = 24V, TC = 25°C, IOUT = 10A
[2]
Disabled
Enabled (no load)
8
24
36
V
1.14
A
20
mA
2.0
mA
2.5
mA
1
V/μs
Output Voltage Total Regulation
Output Voltage Trim Range
Line Regulation
Load Regulation
Output Voltage Ripple
Continuous Output
Current Range
Current Limit
Output Specifications
VOUT_DC
VOUT_DC
[2]
[3] [7]
∆VOUT (∆VIN) @25°C, 8V < VIN < 36V
∆VOUT (∆IOUT)
VOUT_AC
@25°C, 0.5A < IOUT < 10A
IOUT = 5A, COUT = 4 x 100μF, 20MHz BW [4]
IOUT_DC
[5] [7]
IOUT_CL
2.465
2.0
2.500
2.5
0.10
0.10
28
12
2.535
3.1
10
V
V
%
%
mVp-p
A
A
Protection
VIN UVLO Start Threshold
VUVLO_START
7.10
7.60
8.00
V
VIN UVLO Stop Threshold
VUVLO_STOP
6.80
7.25
7.60
V
VIN UVLO Hysteresis
VUVLO_HYS
0.33
V
VIN OVLO Start Threshold
VOVLO_START
37.0
38.4
V
VIN OVLO Stop Threshold
VOVLO_STOP
36.1
V
VIN OVLO Hysteresis
VOVLO_HYS
0.77
V
VIN UVLO/OVLO Fault Delay Time
tf_DLY
Number of the switching freq cycles
128
Cycles
VIN UVLO/OVLO Response Time
tf
500
ns
Output Overvoltage Protection
VOVP
Above VOUT
20
%
Overtemperature
Fault Threshold
TOTP
130
135
140
°C
Overtemperature
Restart Hysteresis
TOTP_HYS
30
°C
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI33xx-x0 evaluation board with 3x4”
dimensions and 4 layer, 2oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control.
[3] Output current capability may be limited and other performance may vary from electrical characteristics when switching frequency or VOUT is modified.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.
[7] Minimum 5V between VIN-VOUT must be maintained or a minimum load of 1mA required.
Cool-Power® ZVS Switching Regulators
Page 12 of 42
Rev 2.4
02/2017
vicorpower.com
800 927.9474