Electrical Specifications (continued)
MV036 SERIES
Figure 7 — Example load step with 100 µF input capacitance and no
output capacitance (MV036F120M010).
General
Figure 8 — Example load step with 100 µF input capacitance and no
output capacitance (MV036F120M010).
Parameter
MTBF (MV036F030M040)
MIL-HDBK-217F
Isolation specifications
Voltage
Capacitance
Resistance
Agency approvals
Mechanical
Weight
Dimensions
Length
Width
Height
Thermal
Over temperature shutdown
Thermal capacity
Junction-to-case thermal impedance (RθJC)
Junction-to-ambient
Min
2,250
10
125
Typ
Max
Unit
Note
4,480,000
806,000
631,000
Hours
25°C, GB
50°C NS
65°C AIC
Vdc
Input to Output
3000
pF
Input to Output
MΩ
Input to Output
cTÜVus
UL /CSA 60950-1, EN 60950-1
CE Marked for Low Voltage Directive and RoHS Recast Directive, as applicable
See Mechanical Drawings, Figures 10 & 11
0.53/ 15
oz /g
1.28/ 32,5
0.87 / 22
0.265 / 6,73
in / mm
in / mm
in / mm
130
135
°C
Junction temperature
9.3
Ws / °C
1.1
°C / W
5.0
°C / W
With 0.25” heat sinkˆ
Auxiliary Pins (Conditions are at 36 Vin, full load, and 25°C ambient unless otherwise specified)
Parameter
Primary Control (PC)
DC voltage
Module disable voltage
Module enable voltage
Current limit
Disable delay time
VTM® Control (VC)
External boost voltage
External boost duration
Min
Typ
Max
Unit
4.8
5.0
5.2
Vdc
2.4
2.5
Vdc
2.5
2.6
Vdc
2.4
2.5
2.9
mA
6
µs
12
14
19
Vdc
10
ms
Note
VC voltage must be applied when module is enabled using PC
Source only
PC low to Vout low
Required for VTM start up without PRM
Maximum duration of VC pulse = 20 ms