Absolute Maximum Ratings
Parameter
+In to -In
PC to -In
VC to -In
+Out to -Out
Isolation voltage
Output current
Peak output current
Output power
Peak output power
Case temperature
Operating junction temperature[a]
Storage temperature
Values
-1.0 to 60
100
-0.3 to 7.0
-0.3 to 19.0
Model specific
2,250
Model specific
1.5 • Iout
120
180
225
245
-55 to 125
-65 to 125
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
A
A
W
W
°C
°C
°C
°C
Notes
For 100 ms
Contact factory
Input to Output
See Table 1
For 1 ms
For 1 ms
MSL 5
MSL 6
M - Grade
M - Grade
Note:
[a] The referenced junction is defined as the semiconductor having the highest temperature. This temperature is monitored by a shutdown comparator.
Electrical Specifications
Input Specs (Conditions are at 36 Vin, full load, and 25°C ambient unless otherwise specified)
Parameter
Input voltage range
Input dV/dt
Input overvoltage turn-on
Input overvoltage turn-off
Input current
No load power dissipation
Min
Typ
See table 1 36
50.5
54.4
55.5
1.5
4.0
Max
50
1
57.5
3.5
7.8
Unit
Vdc
V/µs
Vdc
Vdc
Adc
W
Note
Continuous
Low line to high line
Output Specs (Conditions are at 36 Vin, full load, and 25°C ambient unless otherwise specified)
Parameter
Output voltage
Rated DC current
Peak repetitive current
DC current limit
Current share accuracy
Efficiency
Load capacitance
Output overvoltage setpoint
Output ripple voltage (typ)
No external bypass
10 µF bypass capacitor
Effective switching frequency
Line regulation
Load regulation
Transient response
Response time
Recovery time
Min
Typ
Max
See Table 1
K•VIN – IO • ROUT NOM
0
100
150%
160%
5
10
Unit
Vdc
Vdc
Adc
IMAX (A)
INOM (A)
%
50
2
2.5
0.99K
ROUTMIN
110%
3.0
K
200
1
115%
VOUT MAX
250
20
3.6
1.01K
ROUTMAX
mV
mV
MHz
mΩ
ns
µs
Note
No load
Full load
26 - 50 VIN See Table 1
Max pulse width 1ms, max duty cycle 10%,
baseline power 50%
Module will shut down when current limit is reached
or exceeded
See Table 2, Page 3
See Table 2 when used with PRM
See Figures 2 and 5
See Figure 6
Model dependent
VOUT = K•VIN at no load, See Table 1
See Table 1
See Figures 7 and 8
See Figures 7 and 8
MIL-COTS Chip Transformer