English
Language : 

MV036F022M055-CB Datasheet, PDF (3/10 Pages) Vicor Corporation – MV036 SERIES
End of Life - Please see First Page
Electrical Specifications (continued)
MIL-COTS VTM® Family Part Numbers and Ranges
Part Number
MV036F011M100
MV036F015M080
MV036F022M055
MV036F030M040
MV036F045M027
MV036F060M020
MV036F072M017*
MV036F090M013
MV036F120M010
MV036F180M007
MV036F240M005
MV036F360M003
K-Factor
1/32
1/24
1/16
1/12
1/8
1/6
1/5
1/4
1/3
1/2
2/3
1
Table 1 — VTM part numbers
* Low line input voltage 32 V
**Low line input voltage 28 V
Rated Output
Current (A)
100
80
55
40
27
20
16.6
13.3
10.0
6.7
5.0
3.3
No Load Output Voltage (Vdc)
@26 Vin
@ 50 Vin
0.82
1.55
1.1
2.0
1.63
3.1
2.2
4.1
3.3
6.2
4.3
8.3
6.4*
10
6.5
12.5
8.7
16.6
14**
25
17.4
33
26
50
MV036 SERIES
Rout (mΩ)
Min
Nom
Max
0.5
0.9
1.3
1.0
1.3
1.5
1.4
1.75
2.0
1.45
2.8
3.6
3.5
6.0
7.1
5.0
8.0
10
6.0
9.6
12
6.9
11.5
13.9
25
31
40
27.5
43.6
60.0
49.3
79.0
98.0
140
188
210
Part Number
Typical Full Load Efficiency at nom Vout (%) Typical Half Load Efficiency at nom Vout (%) Maximum Load Capacitance (µF)
MV036F011M100
MV036F015M080
MV036F022M055
MV036F030M040
MV036F045M027
MV036F060M020
MV036F072M017
MV036F090M013
MV036F120M010
MV036F180M007
MV036F240M005
MV036F360M003
89.2
91.9
94
94
94.6
95.3
96.2
96.2
94.8
95.8
95.0
96
89.3
48128
92.3
27072
94.5
12032
94.8
6768
95.6
3008
96.0
1692
96.2
1175
95.5
752
94.9
423
95.2
188
94.8
106
96
47
Table 2 — Typical efficiency and maximum load capacitance, by part number
Control Pin Functions
VC – VTM Control
The VC port is multiplexed. It receives the initial VCC voltage from an
upstream PRM®, synchronizing the output rise of the VTM® with the
output rise of the PRM. Additionally, the VC port provides feedback to
the PRM to compensate for the VTM output resistance. In typical
applications using VTMs powered from PRMs, the PRM’s VC port
should be connected to the VTM VC port.
The VC port is not intended to be used to supply VCC voltage to the
VTM for extended periods of time. If VC is being supplied from a
source other than the PRM, the voltage should be removed after 20 ms.
PC – Primary Control
The Primary Control (PC) port is a multifunction port for controlling the
VTM as follows:
Disable – If PC is left floating, the VTM output is enabled. To
disable the output, the PC port must be pulled lower than 2.4 V,
referenced to -In. Optocouplers, open collector transistors or relays
can be used to control the PC port. Once disabled, 14 V must be
re-applied to the VC port to restart the VTM.
Primary Auxiliary Supply – The PC port can source up to 2.4 mA
at 5 Vdc.
MIL-COTS Chip Transformer
Page 3 of 10
Rev 2.9
01/2014
vicorpower.com
800 927.9474