9.2.6 High Frequency Pole Design (C2):
Using Equation [3], C2 should be selected so that FP2 is at
least one decade above FCMAX and prior to the gain
bandwidth product of the operational amplifier (10MHz for
this example). For applications with a higher desired
crossover frequency the use of a high gain bandwidth
product amplifier may be necessary to ensure that the real
pole can be set at least one decade above the maximum
crossover frequency.
9.2.7 Verifying Stability:
The preferred method for verifying stability is to use a
network analyzer, measuring the closed loop response
across various lines and load conditions.
In the absence of a network analyzer, a load step transient
response can be used in order to estimate stability.
Figure 28 illustrates an example of a load step response.
Equation [4] can be used to predict the phase margin
based on the ratio of the “kick” to “droop” (as defined in
Fig. 28).
k
Vout
d
time
Iout
time
Figure 28 – load step response example and “droop”
vs. “kick” definition