English
Language : 

PRM48BF480T500A00 Datasheet, PDF (20/45 Pages) Vicor Corporation – PRM™ Regulator
PRM48B x 480 y 500A00
TYPICAL PERFORMANCE CHARACTERISTICS
The following figures present typical performance at TC = 25ºC, unless otherwise noted.
DC Safe Operating Area
12.0
600
10.0
500
8.0
400
6.0
300
4.0
200
2.0
100
0.0
0
20
25
30
35
40
45
50
55
60
Output Voltage [V]
Current
Power
Figure 1 DC Safe Operating Area (SOA)
Efficiency & Power Dissipation
VOUT = 20 V TCASE =-40 °C
98
18
96
16
94
14
92
12
90
10
88
8
86
6
84
4
82
2
0
1
2
3
4
5
6
7
8
9
10
11
Load Current [A]
VIN: 38 V
VIN: 48 V
VIN: 55 V
Figure 4: Total efficiency and power dissipation vs. VIN and IOUT
VOUT = 20 V, TCASE = -40 °C
No Load Power Dissipation vs. Line
4
Module Enabled - 48 Vout
3.5
3
2.5
2
1.5
1
38
40
42
44
46
48
50
52
54
56
Input Voltage [V]
TCASE: ‐40°C
TCASE: 25°C
TCASE: 100°C
Figure 2: No Load Power Dissipation vs. VIN, module enabled
Efficiency & Power Dissipation
VOUT = 20 V TCASE =25 °C
98
18
96
16
94
14
92
12
90
10
88
8
86
6
84
4
82
2
0
1
2
3
4
5
6
7
8
9
10
11
Load Current [A]
VIN: 38 V
VIN: 48 V
VIN: 55 V
Figure 5: Total efficiency and power dissipation vs. VIN and IOUT
VOUT = 20 V, TCASE = 25 °C
No Load Power Dissipation vs. Line
Module Disabled - ENABLE = Low
1
0.9
0.8
0.7
0.6
0.5
0.4
38
40
42
44
46
48
50
52
54
56
Input Voltage [V]
TCASE: ‐40°C
TCASE: 25°C
TCASE: 100°C
Figure 3: No Load Power Dissipation vs. VIN, module disabled
Efficiency & Power Dissipation
VOUT = 20 V TCASE =100 °C
98
20
96
18
94
16
92
14
90
12
88
10
86
8
84
6
82
4
80
2
0
1
2
3
4
5
6
7
8
9
10
11
Load Current [A]
VIN: 38 V
VIN: 48 V
VIN: 55 V
Figure 6: Total efficiency and power dissipation vs. VIN and IOUT
VOUT = 20 V, TCASE = 100 °C
- 20 -
Rev. 1.0
11/2012