Table 5. Environmental Compliance
Parameter
PreHeat Time
Ramp Up
Time Above 217°C
Time To Peak Temperature
Time At 260°C
Ramp Down
Symbol
t
S
R
UP
t
L
t
AMP-B
t
P
R
DN
The device has been qualified to meet the JEDEC
standard for Pb-Free assembly. The temperatures and
time intervals listed are based on the Pb-Free small
body requirements. The temperatures refer to the
topside of the package, measured on the package
body surface. The CD-700 device is hermetically sealed
so an aqueous wash is not an issue.
Value
60 sec Min, 180 sec Max
3°C/sec Max
60 sec Min, 150 sec Max
480 sec Max
20 sec Min, 40 sec Max
6°C/sec Max
Tape and Reel
Figure 10. Suggested IR Profile
Table 6. Tape and Reel Information
Tape Dimensions (mm)
A
B
C
D
E
16
7.5
1.5
4
8
Figure 11. Tape and Reel
Reel Dimensions (mm)
F
G
H
I
J
1.5
20.2
13
50
6
K
L #/Reel
16.4 178 200