English
Language : 

TA1360AFG Datasheet, PDF (89/110 Pages) Toshiba Semiconductor – YCbCr/YPbPr Signal and Sync Processor for Digital TV, Progressive Scan TV and Double Scan TV
TA1360AFG
Note
No.
Characteristics
SW68
T26 Text ACL
A
characteristic
SW67
B
SW66
B
Test Conditions
SW Mode
SW26 SW25 SW24
A
A
B
SW21
A
SW19
A
SW18
A 1.
Test Method
Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
2. Apply 5-V external voltage to pin 2.
3. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 24.
4. Measure pin 12 picture period amplitude, vTXACL1.
5. Apply “pin 78 DC voltage − 0.8 V” to pin 78 from external power supply, and measure pin
12-picture period amplitude, vTXACL2.
6. Apply “pin 78 DC voltage − 1.3 V” to pin 78 from external power supply, and measure pin
12-picture period amplitude, vTXACL3.
7. TXACL1 = −20 × log (vTXACL2/vTXACL1)
TXACL2 = −20 × log (vTXACL3/vTXACL1)
T27 Analog OSD
A
gain
B
B
A
A
A
A
A
A 1. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
or
or
or
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
B
B
B 2. Apply 5-V external voltage to pins 1 and 80.
3. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 18.
4. Measure pin 12 picture period amplitude, v12R.
5. Repeat the steps 3 and 4 above with the following pins: Input from pin 19, and measure pin
13. Input from pin 21 and measure pin 14. (v13G and v14B)
6. Calculate the following equations.
GOSDR = v12R/0.2 GOSDG = v13G/0.2 GOSDB = v14B/0.2
T28 Analog OSD
A
B
B
A
A
A
A
A
A 1. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
input white
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
peak slice
level
2. Apply 5-V external voltage to pins 1 and 80.
3. Input signal 2 from pin 18. Gradually increase picture amplitude, and measure picture period
amplitude voltage when output from pin 12 is clipped.
4. Repeat the step 3 above with the following pins: Input from pin 19, and measure pin 13. Input
from pin 21, and measure pin 14.
T29 Analog OSD
A
B
B
A
A
A
A
A
A 1. Input signal 1(f0 = 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
black peak
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
limit level
2. Apply 5-V external voltage to pins 1 and 80.
3. Input signal 2 from pin 18. Gradually decrease picture amplitude, and measure picture period
amplitude voltage when output from pin 12 is clipped.
4. Repeat the step 3 above with the following pins: Input from pin 19, and measure pin 13. Input
from pin 21, and measure pin 14.
89