English
Language : 

MUX508 Datasheet, PDF (9/37 Pages) Texas Instruments – Low-Capacitance, Low-Charge-Injection, Precision, Analog Multiplexers
www.ti.com
Electrical Characteristics: Single Supply(1) (continued)
at TA = 25°C, VDD = 12 V, and VSS = 0 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
POWER SUPPLY
VDD supply current
VSS supply current
All VA = 0 V or 3.3 V,
VS= 0 V, VEN = 3.3 V
All VA = 0 V or 3.3 V,
VS = 0 V, VEN = 3.3 V
TA = –40°C to +85°C
TA = –40°C to +125°C
TA = –40°C to +85°C
TA = –40°C to +125°C
MUX508, MUX509
SBAS758A – JANUARY 2016 – REVISED MARCH 2016
MIN
TYP
MAX UNIT
42
53
56
µA
77
23
38
31
µA
51
Copyright © 2016, Texas Instruments Incorporated
Product Folder Links: MUX508 MUX509
Submit Documentation Feedback
9