English
Language : 

MUX508 Datasheet, PDF (20/37 Pages) Texas Instruments – Low-Capacitance, Low-Charge-Injection, Precision, Analog Multiplexers
MUX508, MUX509
SBAS758A – JANUARY 2016 – REVISED MARCH 2016
www.ti.com
8.9 Off Isolation
Off isolation is defined as the voltage at the drain pin (D, DA, or DB) of the MUX50x when a 1-VRMS signal is
applied to the source pin (Sx, SxA, or SxB) of an off-channel. Figure 33 shows the setup used to measure off
isolation. Use Equation 2 to compute off isolation.
VDD
0.1 µF
VSS
0.1 µF
VDD
S
VSS
50 Ÿ
Network Analyzer
50
VS
D
GND
VOUT
RL
50 Ÿ
Figure 33. Off Isolation Measurement Setup
Off Isolation
20
˜
§
Log¨
VOUT
·
¸
© VS ¹
(2)
8.10 Channel-to-Channel Crosstalk
Channel-to-channel crosstalk is defined as the voltage at the source pin (Sx, SxA, or SxB) of an off-channel,
when a 1-VRMS signal is applied at the source pin of an on-channel. Figure 34 shows the setup used to measure,
and Equation 3 is the equation used to compute, channel-to-channel crosstalk.
VDD
0.1 µF
VSS
0.1 µF
Network Analyzer
VOUT
RL
50 Ÿ
VS
VDD
VSS
S1
S2
GND
R
50 Ÿ
Figure 34. Channel-to-Channel Crosstalk Measurement Setup
Channel-to-Channel Crosstalk
20
˜
§
Log¨
VOUT
·
¸
© VS ¹
(3)
20
Submit Documentation Feedback
Product Folder Links: MUX508 MUX509
Copyright © 2016, Texas Instruments Incorporated