English
Language : 

MUX508 Datasheet, PDF (25/37 Pages) Texas Instruments – Low-Capacitance, Low-Charge-Injection, Precision, Analog Multiplexers
www.ti.com
MUX508, MUX509
SBAS758A – JANUARY 2016 – REVISED MARCH 2016
Feature Description (continued)
9.3.4 Rail-to-Rail Operation
A valid analog signal for the MUX50x ranges from VSS to VDD. The input signal to the MUX50x can swing from
VSS to VDD without any significant degradation in performance. The on-resistance of the MUX50x varies with
input signal, as shown in Figure 41
250
VDD = 13.5 V VDD = 15 V
200
VSS = ±13.5 V VSS = ±15 V
150
100
50
VDD = 18 V
VSS = ±18 V
VDD = 16.5 V
VSS = ±16.5 V
0
±20 ±15 ±10 ±5 0
5 10 15 20
Source or Drain Voltage (V)
C001
Figure 41. On-Resistance vs Source or Drain Voltage
9.4 Device Functional Modes
When the EN pin of the MUX50x is pulled high, one of the switches is closed based on the state of the address
lines. When the EN pin is pulled low, all the switches are in an open state irrespective of the state of the address
lines. The EN pin can be connected to VDD (as high as 36 V).
Copyright © 2016, Texas Instruments Incorporated
Product Folder Links: MUX508 MUX509
Submit Documentation Feedback
25