English
Language : 

CC430F613 Datasheet, PDF (83/120 Pages) Texas Instruments – MSP430 SoC with RF Core
www.ti.com
ECCN 5E002 TSPA - Technology / Software Publicly Available
CC430F613x
CC430F612x
CC430F513x
SLAS554E – MAY 2009 – REVISED NOVEMBER 2010
Typical Output Power, 315 MHz(1)
PARAMETER
PATABLE Setting
Output power,
315 MHz
0xC0 (max)
0xC4 (10 dBm)
0xC6 (default)
0x51 (0 dBm)
0x29 (-6 dBm)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
11.9
11.8
11.8
10.3
10.3
10.3
9.3
dBm
0.7
0.6
0.7
-6.8
-5.6
-5.3
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 46).
Typical Output Power, 433 MHz(1)
PARAMETER
PATABLE Setting
Output power,
433 MHz
0xC0 (max)
0xC4 (10 dBm)
0xC6 (default)
0x50 (0 dBm)
0x2D (-6 dBm)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
12.6
12.6
12.6
10.3
10.2
10.2
10.0
dBm
0.3
0.3
0.3
-6.4
-5.4
-5.1
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 46).
Typical Output Power, 868 MHz(1)
PARAMETER
PATABLE Setting
0xC0 (max)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
11.9 11.2 10.5 11.9 11.2 10.5 11.9 11.2 10.5
Output power,
868 MHz
0xC3 (10 dBm)
0xC6 (default)
0x8D (0 dBm)
10.8 10.1 9.4 10.8 10.1 9.4 10.7 10.1 9.4
8.8
dBm
1.0 0.3 -0.3 1.1 0.3 -0.3 1.1 0.3 -0.3
0x2D (-6 dBm)
-6.5 -6.8 -7.3 -5.3 -5.8 -6.3 -4.9 -5.4 -6.0
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 46).
Typical Output Power, 915 MHz(1)
PARAMETER
PATABLE Setting
0xC0 (max)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
12.2 11.4 10.6 12.1 11.4 10.7 12.1 11.4 10.7
Output power,
915 MHz
0xC3 (10 dBm)
0xC6 (default)
0x8D (0 dBm)
11.0 10.3 9.5 11.0 10.3 9.5 11.0 10.3 9.6
8.8
dBm
1.9 1.0 0.3 1.9 1.0 0.3 1.9 1.1 0.3
0x2D (-6 dBm)
-5.5 -6.0 -6.5 -4.3 -4.8 -5.5 -3.9 -4.4 -5.1
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 46).
Copyright © 2009–2010, Texas Instruments Incorporated
Submit Documentation Feedback
83