Analog-to-Digital Converter (ADC)
Register 8: ADC Trigger Source Select (ADCTSSEL), offset 0x01C
If a PWM Generator n is selected as a trigger source through the EMn bit field in the ADC Event
Multiplexer Select (ADCEMUX) register, the ADCTSSEL register is programmed to identify in
which PWM module instance the generator creating the trigger is located. The register resets to
0x0000.0000, which selects PWM module 0 for all generators. Note that field PS3 selects the PWM
module that maps to Generator 3; PS2 selects the PWM module that maps to Generator 2, and so
on.
ADC Trigger Source Select (ADCTSSEL)
ADC0 base: 0x4003.8000
ADC1 base: 0x4003.9000
Offset 0x01C
Type RW, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
PS3
reserved
PS2
reserved
Type RO
RO
RW
RW
RO
RO
RO
RO
RO
RO
RW
RW
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
PS1
reserved
PS0
reserved
Type RO
RO
RW
RW
RO
RO
RO
RO
RO
RO
RW
RW
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:30
29:28
Name
reserved
PS3
Type
RO
RW
Reset
0x0
0x0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
Generator 3 PWM Module Trigger Select
This field selects in which PWM module the generator 3 trigger is located.
Value Description
0x0
Use Generator 3 (and its trigger) in PWM module 0
0x1
Use Generator 3 (and its trigger) in PWM module 1
0x2 - 0x3 reserved
27:22
21:20
reserved
PS2
RO
0x0
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
RW
0x0
Generator 2 PWM Module Trigger Select
This field selects in which PWM module the Generator 2 trigger is
located.
Value Description
0x0
Use Generator 2 (and its trigger) in PWM module 0
0x1
Use Generator 2 (and its trigger) in PWM module 1
0x2 - 0x3 reserved
19:14
reserved
RO
0x0
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.