System Control
Bit/Field
9
8
7:6
5
4
3
2
1
0
Name
QEI1
QEI0
reserved
SSI1
SSI0
reserved
UART2
UART1
UART0
Type
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0x0
0x0
0
0x0
0x0
0
0x0
0x0
0x0
Description
QEI1 Clock Gating Control
This bit controls the clock gating for QEI module 1. If set, the module
receives a clock and functions. Otherwise, the module is unclocked and
disabled. If the module is unclocked, a read or write to the module
generates a bus fault.
QEI0 Clock Gating Control
This bit controls the clock gating for QEI module 0. If set, the module
receives a clock and functions. Otherwise, the module is unclocked and
disabled. If the module is unclocked, a read or write to the module
generates a bus fault.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
SSI1 Clock Gating Control
This bit controls the clock gating for SSI module 1. If set, the module
receives a clock and functions. Otherwise, the module is unclocked and
disabled. If the module is unclocked, a read or write to the module
generates a bus fault.
SSI0 Clock Gating Control
This bit controls the clock gating for SSI module 0. If set, the module
receives a clock and functions. Otherwise, the module is unclocked and
disabled. If the module is unclocked, a read or write to the module
generates a bus fault.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
UART2 Clock Gating Control
This bit controls the clock gating for UART module 2. If set, the module
receives a clock and functions. Otherwise, the module is unclocked and
disabled. If the module is unclocked, a read or write to the module
generates a bus fault.
UART1 Clock Gating Control
This bit controls the clock gating for UART module 1. If set, the module
receives a clock and functions. Otherwise, the module is unclocked and
disabled. If the module is unclocked, a read or write to the module
generates a bus fault.
UART0 Clock Gating Control
This bit controls the clock gating for UART module 0. If set, the module
receives a clock and functions. Otherwise, the module is unclocked and
disabled. If the module is unclocked, a read or write to the module
generates a bus fault.
462
June 12, 2014
Texas Instruments-Production Data