English
Language : 

TLC2942_06 Datasheet, PDF (7/29 Pages) Texas Instruments – HIGH-PERFORMANCE DUAL PHASE-LOCKED LOOP BUILDING BLOCK
TLC2942
HIGH-PERFORMANCE DUAL PHASE-LOCKED LOOP BUILDING BLOCK
SLAS146B – NOVEMBER 1996 – REVISED JUNE 1997
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage (each supply), VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage range (each input), VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VDD + 0.5 V
Input current (each input), II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output current (each output), IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Continuous total power dissipation, at (or below) TA = 25°C (see Note 2) . . . . . . . . . . . . . . . . . . . . . . 1160 mW
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 20°C to 75°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to network GND.
2. For operation above 25°C free-air temperature, derate linearly at the rate of 9.3 mW/°C.
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage, VDD (each supply, see Note 3)
VDD = 3 V
VDD = 5 V
Input voltage, VI, (all inputs except VCOIN1, VCOIN2)
Output current, IO (each output)
VCO control voltage at each VCOIN1, VCOIN2
Lock frequency, (each VCO) (×1 output)
Lock frequency, (each VCO) (×1/2 output)
Bias resistor, (each BIAS), RBIAS1, RBIAS2
VDD = 3 V
VDD = 5 V
VDD = 3 V
VDD = 5 V
VDD = 3 V
VDD = 5 V
2.85
3 3.15
V
4.75
5 5.25
0
VDD V
0
± 2 mA
0.9
VDD V
14
21
MHz
22
50
7
10.5
MHz
11
25
2.2 3.3 4.3
kΩ
1.5 2.2 3.3
Operating temperature, TA
–20
75 °C
NOTE 3: It is recommended that LOGIC VDD1 and VCO VDD1 or LOGIC VDD2 and VCO VDD2 should be at the same voltage and separated from
each other.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
7