English
Language : 

OPA189 Datasheet, PDF (7/34 Pages) Texas Instruments – Precision, 36-V, 14-MHz, MUX-Friendly Low-Noise, Rail-to-Rail Output, Zero-Drift Operational Amplifiers
www.ti.com
OPA189, OPA2189, OPA4189
SBOS830 – JUNE 2017
7 Specifications
7.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)
Supply voltage
Signal input pins
Output short circuit(2)
Temperature
VS = (V+) – (V–)
Voltage
Current
Operating, TA
Junction, TJ
Storage, Tstg
Single-supply
Dual-supply
Common-mode
Differential
MIN
(V–) – 0.5
Continuous
–55
–65
MAX
40
±20
(V+) + 0.5
(V+) – (V–) + 0.2
±10
Continuous
150
150
150
UNIT
V
mA
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Short-circuit to ground, one amplifier per package.
7.2 ESD Ratings
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-C101(2)
VALUE
±4000
±1000
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
7.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
Supply voltage, VS = (V+) – (V–)
Specified temperature
Single-supply
Dual-supply
MIN
4.5
±2.25
–40
NOM
MAX
36
±18
125
UNIT
V
°C
Copyright © 2017, Texas Instruments Incorporated
Submit Documentation Feedback
7
Product Folder Links: OPA189 OPA2189 OPA4189