7 Specifications
7.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)
Supply voltage range
AVDD to GND
DVDD to GND
IOVDD to GND
AVCC to GND
AVEE to GND
AVSSA,B,C,D to AVEE
AVCC to AVSSA,B,C,D
AVCC to AVEE
DGND to AGND
ADC_[0-11] analog input voltage to GND
ADC_[0-11] analog input current
LV_ADC[12-16] analog input voltage to GND
LV_ADC[12-16] analog input current
DAC outputs to GND
Terminal voltage/
Current range
REF_CMP to GND
REF_OUT[1-2] to GND
VRANGE[A-D] to GND
CS, SCLK, SDI and RESET to GND
SDO to GND
GPIO[0-7] to GND
GPIO[0-7] sinking current
Operating temperature range
Junction temperature range (TJ max)
MIN
-0.3
-0.3
-0.3
-0.3
-13
-0.3
-0.3
-0.3
-0.3
–13
-10
-0.3
-10
AVSS - 0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-40
-40
MAX
+6
+6
DVDD
+18
+0.3
+13
+26
+26
+0.3
+13
+10
AVDD + 0.3
+10
AVCC + 0.3
AVDD + 0.3
AVDD + 0.3
AVDD + 0.3
IOVDD + 0.3
IOVDD + 0.3
IOVDD + 0.3
5
+125
+150
UNIT
V
V
V
V
V
V
V
V
V
V
mA
V
mA
V
V
V
V
V
V
V
mA
°C
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
7.2 Handling Ratings
PARAMETER
DEFINITION
Tstg
VESD (1)
Storage temperature range
Human body model (HBM) ESD stress voltage(2)
Charged device model (CDM) ESD stress voltage(3)
MIN
MAX
UNIT
-40
+150
°C
2.0
kV
750
V
(1) Electrostatic discharge (ESD) to measure device sensitivity and immunity to damage caused by assembly line electrostatic discharges in
to the device.
(2) Level listed above is the passing level per ANSI, ESDA, and JEDEC JS-001. JEDEC document JEP155 states that 500-V HBM allows
safe manufacturing with a standard ESD control process.
(3) Level listed above is the passing level per EIA-JEDEC JESD22-C101. JEDEC document JEP157 states that 250-V CDM allows safe
manufacturing with a standard ESD control process.
6
Submit Documentation Feedback
Product Folder Links: AMC7832
Copyright © 2014, Texas Instruments Incorporated