AMC7832 Datasheet, PDF (45/70 Pages) Texas Instruments – AMC7832 12-Bit Analog Monitor and Control Solution with Multi-Channel ADC, Bipolar DACs, Temperature Sensor and GPIO Ports
www.ti.com
AMC7832
SLAS836 – MARCH 2014
8.5.4 General Device Configuration: Address 0x10 – 0x17
Table 16. Register name: ADC Configuration – Address: 0x10, Default: 0x00 (READ/WRITE)
REGISTER
NAME
ADC Config
ADDRESS
0x10
BIT NAME
DESCRIPTION
DEFAULT
VALUE
7
CMODE
ADC Conversion Mode Bit. This bit selects the ADC conversion
0
mode.
0: Direct mode. The analog inputs specified in the ADC channel
registers are converted sequentially one time. When one set of
conversions is complete, the ADC is idle and waits for a new
trigger.
1: Auto mode. The analog inputs specified in the AMC channel
registers are converted sequentially and repeatedly. When one
set of conversions is complete, the ADC multiplexer returns to
the first channel and repeats the process. In this mode data
should be read synchronously with the DAV terminal.
6:5 CONV-RATE[1:0] ADC Conversion rate bits
00
4
ADC-REF-BUFF ADC Reference Buffer bit. This bit must be set to 1 after device
0
power-up to enable the internal reference buffer driving the ADC.
0: ADC reference buffer is disabled.
1: ADC reference buffer is enabled.
3:0 Reserved
Reserved for factory use
0000
Table 17. Register name: False Alarm Configuration – Address: 0x11, Default: 0x70 (READ/WRITE)
REGISTER
NAME
False Alarm
Config
ADDRESS
0x10
BIT NAME
DESCRIPTION
7:5 CH-FALR-CT[2:0] False alarm protection for ADC channels.
4:3 TEMP-FALR-
CT[1:0]
2:0 Reserved
CH-FALR-CT
N
CONSECUTIVE
SAMPLES
BEFORE
ALARM IS SET
000
1
001
4
010
8
011
16 (default)
100
32
101
64
110
128
111
256
False alarm protection for temperature sensor.
TEMP-FALR-CT
00
01
10
11
Reserved for factory use
N
CONSECUTIVE
SAMPLES
BEFORE
ALARM IS SET
1
2
4 (default)
8
DEFAULT
VALUE
011
10
000
Copyright © 2014, Texas Instruments Incorporated
Product Folder Links: AMC7832
Submit Documentation Feedback
45