English
Language : 

BQ2084DBTR-V150 Datasheet, PDF (59/69 Pages) Texas Instruments – SBS v1.1-COMPLIANT GAS GAUGE WITH LED DELAY
bq2084-V150
www.ti.com
SLUS758 – JUNE 2007
SSTRING
When this bit is set, it enables an additional 15 characters of storage for both SBS.ManufacturerName( ) and
SBS.DeviceName( ). (Storage is in separate area of data flash)
0 ManufacturerName( ) and DeviceName( ) strings are 11 and 7 characters respectively
1 ManufacturerName( ) and DeviceName( ) strings are 26 and 22 characters respectively
NVCELL
When this bit is set, it forces SBS.VCELL1..4( ) to be accessible via alternative commands.
0 SBS.VCELL1..4( ) available via 0x3c-0x3f
1 SBS.VCELL1..4( ) available via 0x38-0x3b
CCDSG
When this bit is set, it forces SBS.ChargingCurrent( ) to be reported as 0 when SBS.BatteryStatus( )
DISCHARGING is also set.
0 SBS.ChargingCurrent( ) is not modified just because SBS.BatteryStatus( ) DISCHARGING is set.
1 SBS.ChargingCurrent( ) is set to 0 when SBS.BatteryStatus( ) DISCHARGING is set.
SOCL
When this bit is set, it limits both RSOC and ASOC to 99% until a valid charge termination is detected.
0 RSOC and ASOC are not limited.
1 RSOC and ASOC are limited to 99% until charge termination.
CVFC
When this bit is set, it causes SBS.ChargingVoltage( ) to be set to 0 when SBS.BatteryStatus( ) FC = 1.
0 SBS.ChargingVoltage( ) is not modified
1 SBS.ChargingVoltage( ) is set to 0 when FC = 1
DEPFET
When this bit is set, it enables the CHG FET to be turned on when in depleted mode and when the lowest cell
voltage reading is greater than the precharge voltage threshold
0 No FET action taken
1 CHG FET turned on
Constants and String Data
Specification Information
Specification Information DF 0x06-0x07 stores the default value for the SpecificationInfo() function. It is stored in
data flash in the same format as the data returned by the SpecificationInfo().
Manufacture Date
Manufacture Date DF 0x08-0x09 stores the default value for the ManufactureDate() function. It is stored in data
flash in the same format as the data returned by the ManufactureDate().
Serial Number
Serial Number DF 0x0a-0x0b stores the default value for the SerialNumber() function. It is stored in data flash in
the same format as the data returned by the SerialNumber().
Submit Documentation Feedback