SOV
The SOV bit indicates a safety overvoltage occurred which if enabled by PF Config would cause the SAFE
output to activate.
0 SOV fault not detected (default)
1 SOV fault detected
SOTC
The SOTC bit indicates a safety overtemperature in charge occurred which if enabled by PF Config would
cause the SAFE output to activate.
0 SOTC fault not detected (default)
1 SOTC fault detected
SOTD
The SOTD bit indicates a safety overtemperature in discharge occurred which if enabled by PF Config would
cause the SAFE output to activate.
0 SOTD fault not detected (default)
1 SOTD fault detected
AFE
The AFE bit indicates an AFE integrity fault state occurred which if enabled by PF Config would cause the
SAFE output to activate.
0 AFE is operating correctly (default)
1 AFE Integrity check fail limit reached
CIM
The CIM bit indicates that a severe cell imbalance occurred during charging, which if enabled by PF Config,
would cause the SAFE output to activate.
0 All cells are within the Cell Imbalance Threshold (default)
1 There is a severe cell imbalance
FETF
The FETF bit indicates a FET or FET driver failure occurred, which if enabled by PF Config would cause the
SAFE output to activate.
0 The FETs are operating normally (default)
1 The FETs or FET drivers have a fault
PFIN
The PFIN bit is used to indicate that the output of the 2nd level protector has activated.
0 The PFIN input is high (default)
1 The PFIN input drive and held low by 2nd level protector output
FPP
The FPP bit is used to indicate that current has been detected when the fuse has been set to be blown.
0 Current not detected with fuse blown
1 Current detected with fuse blown
24