English
Language : 

SN74BCT979 Datasheet, PDF (5/10 Pages) Texas Instruments – 9-BIT REGISTERED BTL TRANSCEIVER WITH PARITY GENERATOR/CHECKER
SN74BCT979
9ĆBIT REGISTERED BTL TRANSCEIVER
WITH PARITY GENERATOR/CHECKER
SCBS115A − OCTOBER 1990 − REVISED NOVEMBER 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1): B1−B8, BPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 5.5 V
Other inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Voltage range applied to any output in the disabled or power-off state, VO . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Voltage range applied to any output in the high state, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC
Input clamp current, IIK (VI < 0) (A port) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30 mA
Current into any output in the low state, IO: A port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 mA
B port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 mA
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Maximum power dissipation at TA = 55°C (in still air) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.85 W
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input negative-voltage rating may be exceeded if the input clamp-current rating is observed.
recommended operating conditions (see Note 2)
VCC Supply voltage
VIH High-level input voltage
B1 −B8, BPAR
Other inputs
VIL Low-level input voltage
B1 −B8, BPAR
Other inputs
VOH
IIK
IOH
High-level output voltage
Input clamp current
High-level output current
IOL Low-level output current
B1 −B8, BPAR
AO1 −AO8, APARO, ERRA, ERRB
AO1 −AO8, APARO, ERRA, ERRB
B1 −B8, BPAR
∆t /∆v Input transition rise or fall rate
Outputs enabled
TA
Operating free-air temperature
NOTE 2: Unused or floating pins (input or I/O) must be held high or low.
MIN NOM MAX UNIT
4.5
5 5.5 V
1.6
V
2
1.47
V
0.8
2.1 mA
−18 mA
−3 mA
24
mA
100
10 ns / V
0
70 °C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443