English
Language : 

CD74HC652_15 Datasheet, PDF (5/13 Pages) Texas Instruments – High-Speed CMOS Logic Octal-Bus Transceiver/Registers, Three-State
CD74HC652, CD74HCT652
DC Electrical Specifications (Continued)
PARAMETER
Input Leakage
Current
TEST
CONDITIONS
25oC
SYMBOL
II
VI (V)
VCC or
GND
VIS (V) VCC (V) MIN
-
6
-
TYP MAX
- ±0.1
-40oC TO 85oC
MIN MAX
-
±1
Quiescent Device
Current
ICC
VCC or
0
GND
Three- State Leakage VIL or VIH VO =
-
Current
VCC or
GND
6
-
-
8
-
80
6
-
- ±0.5
-
±5.0
HCT TYPES
High Level Input
Voltage
Low Level Input
Voltage
High Level Output
Voltage
CMOS Loads
VIH
-
-
4.5 to 2
-
-
2
-
5.5
VIL
-
-
4.5 to -
- 0.8
-
0.8
5.5
VOH
VIH or -0.02
4.5
4.4
-
-
4.4
-
VIL
High Level Output
Voltage
TTL Loads
-6
4.5 3.98 -
-
3.84
-
Low Level Output
Voltage
CMOS Loads
VOL
VIH or 0.02
4.5
-
- 0.1
-
0.1
VIL
Low Level Output
Voltage
TTL Loads
6
4.5
-
- 0.26
-
0.33
Input Leakage
Current
II
VCC
0
5.5
-
and
GND
±0.1
-
±1
Quiescent Device
Current
ICC
VCC or
0
5.5
-
-
8
-
80
GND
Three- State Leakage VIL or VIH VO =
-
Current
VCC or
GND
5.5
-
- ±0.5
-
±5.0
Additional Quiescent
∆ICC
VCC
-
4.5 to - 100 360
-
450
Device Current Per
(Note 6) -2.1
5.5
Input Pin: 1 Unit Load
NOTE:
6. For dual-supply systems theoretical worst case (VI = 2.4V, VCC = 5.5V) specification is 1.8mA.
-55oC TO 125oC
MIN MAX UNITS
-
±1
µA
-
160
µA
-
±10
µA
2
-
V
-
0.8
V
4.4
-
V
3.7
-
V
-
0.1
V
-
0.4
V
-
±1
µA
-
160
µA
-
±10
µA
-
490
µA
HCT Input Loading Table
INPUT
UNIT LOADS
OEBA
1.3
OEAB
0.75
Clock A to B, B to A
0.6
Select A, Select B
0.45
Inputs A0-A7, B0-B7
0.3
NOTE: Unit Load is ∆ICC limit specified in DC Electrical Specifica-
tions table, e.g., 360µA max at 25oC.
5