Comparator_A+ (1)
over recommended operating free-air temperature range (unless otherwise noted)
I(DD)
PARAMETER
TEST CONDITIONS
CAON = 1, CARSEL = 0, CAREF = 0
VCC
2.2 V
3V
MIN TYP
25
45
I(Refladder/RefDiode)
CAON = 1, CARSEL = 0, CAREF = 1/2/3,
2.2 V
30
No load at CA0 and CA1
3V
45
VIC
Common-mode input voltage
range (2)
CAON = 1
2.2 V, 3 V
0
V(Ref025)
V(Ref050)
V(RefVT)
V(offset)
Vhys
t(response)
Voltage at 0.25 VCC node /
VCC
Voltage at 0.5 VCC node /
VCC
See Figure 29 and Figure 30
Offset voltage(3)
Input hysteresis
Response time
(low-high and high-low)
PCA0 = 1, CARSEL = 1, CAREF = 1,
No load at CA0 and CA1
PCA0 = 1, CARSEL = 1, CAREF = 2,
No load at CA0 and CA1
PCA0 = 1, CARSEL = 1, CAREF = 3,
No load at CA0 and CA1,
TA = 85°C
CAON = 1
TA = 25°C, Overdrive 10 mV,
Without filter: CAF = 0(4)
(see Figure 26 and Figure 27)
TA = 25°C, Overdrive 10 mV,
With filter: CAF = 1(4)
(see Figure 26 and Figure 27)
2.2 V, 3 V 0.225 0.24
2.2 V, 3 V 0.465 0.48
2.2 V
3V
2.2 V, 3 V
2.2 V, 3 V
2.2 V
3V
2.2 V
3V
360 480
370 490
-42
0.7
100 165
50 120
1.3 1.9
0.7 1.5
MAX
45
65
55
85
UNIT
µA
µA
VCC - 1 V
0.255
0.505
570
mV
580
42 mV
1.8 mV
320
ns
250
3.0
µs
2.5
(1) The leakage current for the Comparator_A+ terminals is identical to Ilkg(Px.y) specification.
(2) Not ensured for TA > 105°C.
(3) The input offset voltage can be cancelled by using the CAEX bit to invert the Comparator_A+ inputs on successive measurements. The
two successive measurements are then summed together.
(4) Response time measured at P2.2/TA0.0/A2/CA4/CAOUT. If the Comparator_A+ is enabled a settling time of 60 ns (typical) is added to
the response time.
Copyright © 2013, Texas Instruments Incorporated
Submit Documentation Feedback
41