English
Language : 

TLC2933_13 Datasheet, PDF (4/24 Pages) Texas Instruments – HIGH-PERFORMANCE PHASE-LOCKED LOOP
TLC2933
HIGHĆPERFORMANCE PHASEĆLOCKED LOOP
SLAS136B − APRIL 1996 − REVISED JANUARY 2002
schematics
VCO block schematic
RBIAS
BIAS
VCO IN
Bias
Control
VCO
Output
Buffer
VCO OUT
VCO INHIBIT
PFD block schematic
Charge Pump
VDD
FIN −A
Detector
PFD OUT
FIN −B
PFD INHIBIT
absolute maximum ratings†
Supply voltage (each supply), VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage range (each input), VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to VDD + 0.3 V
Input current (each input), II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output current (each output), IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Continuous total power dissipation at (or below) TA = 25°C (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . 700 mW
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −20°C to 75°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to network ground terminal.
2. For operation above 25°C free-air temperature, derate linearly at the rate of 5.6 mW/°C.
4