7 Specifications
7.1 Absolute Maximum Ratings(1) (2)
VCC
VIO
VBUS
VBUS
V(Logic_Input)
V(Logic_Output)
IO(RXD)
TJ
5V bus supply voltage range
I/O Level Shifting Voltage Range
Devices with the "V" suffix
CAN Bus I/O voltage range (CANH, Devices without the "H"
CANL)
suffix
CAN Bus I/O voltage range (CANH,
CANL)
Devices with the "H" suffix
Logic input terminal voltage range (TXD, STB)
Logic output terminal voltage range (RXD)
RXD (Receiver) output current
Operating virtual junction temperature range (see Thermal
Information)
MIN
–0.3
–0.3
-58
-70
–0.3
–0.3
-8
–55
MAX
+7
+7
+58
+70
+7 and VI ≤ VIO + 0.3
+7 and VI ≤ VIO + 0.3
+8
150
UNIT
V
mA
°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to ground terminal.
7.2 ESD Ratings
Human Body Model (HBM) ESD stress voltage
Charged Device Model (CDM) ESD stress voltage
Machine Model (MM)
System Level Electro-Static Discharge (ESD)
System Level Electro-Static Discharge (ESD)
ISO7637-2 Transients according to GIFT - ICT CAN
EMC test specification(5)
ISO7637-3 Transients
TEST CONDITIONS
All terminals(1)
CAN bus terminals (CANH, CANL) to GND(2)
All terminals(3)
All terminals(4)
CAN bus terminals
(CANH, CANL) to
GND
SAE J2962-2 per ISO 10605:
Powered Air Discharge
SAE J2962-2 per ISO 10605:
Powered Contact Discharge
CAN bus terminals
(CANH, CANL) to
GND
IEC 61400-4-2: Unpowered Air
Discharge
IEC 61400-4-2: Powered on
Contact Discharge
CAN bus terminals
(CANH, CANL) to
GND
Pulse 1
Pulse 2
Pulse 3a
Pulse 3b
CAN bus terminals
(CANH, CANL) to
GND
Direct Coupling Capacitor
"Slow Transient Pulse" with
100nF coupling capacitor -
Powered
VALUE
±6000
±10000
±750
±200
±15000
±8000
±15000
±8000
–100
+75
–150
+100
±85
UNIT
V
V
V
V
V
(1) Tested in accordance to JEDEC Standard 22, Test Method A114.
(2) Test method based upon JEDEC Standard 22 Test Method A114, CAN bus is stressed with respect to GND.
(3) Tested in accordance to JEDEC Standard 22, Test Method C101.
(4) Tested in accordance to JEDEC Standard 22, Test Method A115.
(5) ISO7637 is a system level transient test. Results given here are specific to the GIFT-ICT CAN EMC Test specification conditions.
Different system level configurations may lead to different results.