English
Language : 

BQ29209-Q1 Datasheet, PDF (4/23 Pages) Texas Instruments – Voltage Protection with Automatic Cell Balance
bq29209-Q1
SLUSC62A – JUNE 2015 – REVISED MARCH 2016
7.2 ESD Ratings
V(ESD) Electrostatic discharge
Human-body model (HBM), per AEC Q100-002(1)
Charged-device model (CDM), per AEC
Q100-011
All pins
Corner pins (VC2, CD,
OUT, and GND)
VALUE
±2000
±500
±750
(1) AEC Q100-002 indicates that HBM stressing shall be in accordance with the ANSI/ESDA/JEDEC JS-001 specification.
www.ti.com
UNIT
V
7.3 Recommended Operating Conditions
Supply voltage, VDD
Input voltage range
VC2–VC1, VC1–GND
Delay time capacitance, td(CD)
CCD (See Figure 9.)
Voltage monitor filter resistance RIN (See Figure 9.)
Voltage monitor filter capacitance CIN (See Figure 9.)
Supply voltage filter resistance RVD (See Figure 9.)
Supply voltage filter capacitance CVD (See Figure 9.)
Cell balance resistance
RCB (See Figure 9 and Protection (OUT) Timing.)
Operating ambient temperature range, TA
MIN NOM MAX UNIT
4
10 V
0
5V
0.1
µF
100
1K
Ω
0.01
0.1
µF
100
1K Ω
0.1
µF
100
4.7K Ω
–40
105 °C
7.4 Thermal Information
THERMAL METRIC(1)
bq29209-Q1
DRB
UNIT
8 PINS
RθJA
RθJC(top)
RθJB
ψJT
ψJB
RθJC(bot)
Junction-to-ambient thermal resistance
Junction-to-case(top) thermal resistance
Junction-to-board thermal resistance
Junction-to-top characterization parameter
Junction-to-board characterization parameter
Junction-to-case(bottom) thermal resistance
50.5
°C/W
25.1
°C/W
19.3
°C/W
0.7
°C/W
18.9
°C/W
5.2
°C/W
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
7.5 Electrical Characteristics
Typical values stated where TA = 25°C and VDD = 7.2 V. Minimum and maximum values stated where TA = –40°C to 105°C
and VDD = 4 V to 10 V (unless otherwise noted).
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
VPROTECT
Overvoltage detection
voltage
4.3
V
VHYS
Overvoltage detection
hysteresis
200 300 400 mV
VOA
Overvoltage detection
accuracy
TA = 25°C
–10
10 mV
VOA_DRIFT
XDELAY
Overvoltage threshold
temperature drift
Overvoltage delay time
scale factor
TA = 0°C to 60°C
TA = –40°C to 110°C
TA = 0°C to 60°C
Note: Does not include external capacitor variation.
TA = –40°C to 110°C
Note: Does not include external capacitor variation.
–0.4
0.4
mV°/C
–0.6
0.6
6
9 12
s/µF
5.5
9 13.5
4
Submit Documentation Feedback
Product Folder Links: bq29209-Q1
Copyright © 2015–2016, Texas Instruments Incorporated