English
Language : 

BQ29209-Q1 Datasheet, PDF (13/23 Pages) Texas Instruments – Voltage Protection with Automatic Cell Balance
www.ti.com
bq29209-Q1
SLUSC62A – JUNE 2015 – REVISED MARCH 2016
9.2.1.3 Application Curve
2
1
0
±1
±2
±3
±4
±5
±6
-40
VC1 V(PROTECT)
VC2 V(PROTECT)
0
25
60
110
Operating Temperature (ƒC)
C001
Figure 10. Average VPROTECT Accuracy (VOA) Across Operation Temperature
9.3 System Example
9.3.1 External Cell Balancing
Higher cell balancing currents can be supported by means of a simple external network, as shown in Figure 11.
CELL2
CELL1
RCB_ EXT
RIN
RIN
Q1
RCLAMP
Q2
1 VC2
CIN
2 VC1
CIN
3 VC1_CB
OUT 8
VDD 7
CB_ EN 6
4 CD
CCD
GND 5
PWR PAD
Figure 11. External Cell Balancing Configuration
PACK +
RVD
CVD
PACK ±
RCLAMP ensures that both Q1 and Q2 remain off when balancing is disabled, and should be sized above 2 kΩ to
prevent excessive internal device current when the balancing network is activated. RCB_EXT determines the value
of the balancing current, and is dependent on the voltage of the balanced cell, as follows:
Ibal
=
VCELL
RCB _EXT
10 Power Supply Recommendations
The recommended power supply for this device is a maximum 10-V operation on the VDD input pin.
Copyright © 2015–2016, Texas Instruments Incorporated
Product Folder Links: bq29209-Q1
Submit Documentation Feedback
13