English
Language : 

CDC2586_08 Datasheet, PDF (3/14 Pages) Texas Instruments – 3.3-V PHASE-LOCK LOOP CLOCK DRIVER
CDC2586
www.ti.com
SCAS337D – FEBRUARY 1993 – REVISED APRIL 2004
Output Configuration A
Output configuration A is valid when any output configured as a 1x frequency output in Table 1 is fed back to
FBIN. The input frequency range for CLKIN is 50 MHz to 100 MHz when using output configuration A. Outputs
configured as 1/2 outputs operate at half the CLKIN frequency, while outputs configured as 1x outputs operate at
the same frequency as CLKIN.
Table 1. Output Configuration A(1)
INPUTS
SEL1
SEL0
L
L
L
H
H
L
H
H
OUTPUTS
1/2×
FREQUENCY
1×
FREQUENCY
None
All
1Yn
2Yn, 3Yn, 4Yn
1Yn, 2Yn
3Yn, 4Yn
1Yn, 2Yn, 3Yn
4Yn
(1) n = 1, 2, 3
Output Configuration B
Output configuration B is valid when any output configured as a 1x frequency output in Table 2 is fed back to
FBIN. The input frequency range for CLKIN is 25 MHz to 50 MHz when using output configuration B. Outputs
configured as 1x outputs operate at the CLKIN frequency, while outputs configured as 2x outputs operate at
double the frequency of CLKIN.
Table 2. Output Configuration B(1)
INPUTS
SEL1
SEL0
L
L
L
H
H
L
H
H
OUTPUTS
1×
FREQUENCY
2×
FREQUENCY
All
None
1Yn
2Yn, 3Yn, 4Yn
1Yn, 2Yn
3Yn, 4Yn
1Yn, 2Yn, 3Yn
4Yn
(1) n = 1, 2, 3
3