English
Language : 

BQ2060SS Datasheet, PDF (3/59 Pages) Texas Instruments – SBS V1.1-COMPLIANT GAS GAUGE IC
bq2060
www.ti.com
ABSOLUTE MAXIMUM RATINGS(1)
SLUS035E – JANUARY 2000 – REVISED OCTOBER 2005
SYMBOL
VCC–Supply voltage
VIN–All other pins
TOPR
TJ
PARAMETER
Relative to VSS
Relative to VSS
Operating temperature
Junction temperature
MIN MAX
–0.3
+6
–0.3
+6
–20
+70
–40 +125
UNIT
V
V
°C
°C
NOTES
Commercial
(1) Permanent device damage may occur if absolute maximum ratings are exceeded. Functional operation should be limited to the
Recommended DC Operating Conditions detailed in this data sheet.
DC ELECTRICAL CHARACTERISTICS
(VCC = 2.7 V to 3.7 V, TOPR = –20°C to 70°C, unless otherwise noted)
SYMBOL
PARAMETER
TEST CONDITIONS
VCC
ICC
ISLP
ILVOUT
IVOUT
VOLS
VIL
VIH
VOL
Supply voltage
Operating current
Low-power storage mode current
VOUT leakage current
VOUT source current
Output voltage low: LED1–LED5, CFC, DFC
Output voltage low: THON, CVON
Input voltage low DISP
Input voltage high DISP
Output voltage low SMBC, SMBD, HDQ16,
ESCL, ESDA
VOUT inactive
1.5 V < VCC < 3.7 V
VOUT inactive
VOUT active,
VOUT = VCC– 0.6 V
IOLS = 5 mA
IOLS = 5 mA
IOL = 1 mA
VILS
Input voltage low SMBC, SMBD, HDQ16,
ESCL, ESDA
VIHS
Input voltage high SMBC, SMBD, HDQ16,
ESCL, ESDA
VAI
IRB
VRBI
ZAI1
ZAI2
Input voltage range VCELL1–4, TS, SRC
RBI data-retention input current
RBI data-retention voltage
Input impedance: SR1, SR2
Input impedance: VCELL1–4, TS, SRC
VRBI > 3 V, VCC < 2.0 V
0–1.25 V
0–1.25 V
MIN
2.7
– 0.2
–5
–0.3
2
TYP
3.3
180
5
MAX
3.7
235
10
0.2
UNIT
V
µA
µA
µA
mA
0.4 V
0.36 V
0.8 V
VCC+ 0.3 V
0.4 V
– 0.3
0.8 V
1.7
VSS– 0.3
10
1.3
10
5
6V
1.25 V
50 nA
V
MΩ
MΩ
VFC CHARACTERISTICS
(VCC = 3.1 to 3.6 V, TOPR = –0°C to 70°C, Unless Otherwise Noted
SYMBOL
PARMETER
TEST CONDITIONS
VSR
VSROS
Input voltagerange,VSR2 and VSR1
VSR input offset
VSR = VSR2– VSR1
VSR2 = VSR1,
autocorrection disabled
VSRCOS
RMVCO
Calibrated offset
Supply voltage gain coefficient(1)
RMTCO
Temperature gain coefficient(1)
INL
Integral nonlinearity error
VCC = 3.3 V
Slope for TOPR = –20°C to 70°C
Total deviation TOPR = –20°C to 70°C
Slope for TOPR = –0°C to 50°C
Total deviation TOPR= –0°C to 50°C
TOPR = 0°C –50°C
(1) RMTCO total deviation is from the nominal gain at 25°C.
MIN
– 0.25
–250
–16
– 0.09
–1.6%
–0.05
–0.6%
TYP MAX UNIT
+0.25 V
–50
250 µV
+16 µ V
0.8
1.2 %/V
+0.09 % /°C
0.1%
+0.05 % /°C
0.1%
0.21%
3