English
Language : 

74ACT11874 Datasheet, PDF (3/7 Pages) Texas Instruments – DUAL 4-BIT D-TYPE EDGE-TRIGGERED FLIP-FLOPS WITH 3-STATE OUTPUTS
ą
74ACT11874
DUAL 4ĆBIT DĆTYPE EDGEĆTRIGGERED FLIPĆFLOPS
WITH 3ĆSTATE OUTPUTS
SCAS212 − D3447, MARCH 1990 − REVISED APRIL 1993
recommended operating conditions
VCC
VIH
VIL
VI
VO
IOH
IOL
Dt /Dv
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
Output voltage
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature
MIN MAX UNIT
4.5 5.5 V
2
V
0.8 V
0 VCC V
0 VCC V
−24 mA
24 mA
0
10 ns/ V
− 40
85 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN TYP MAX
3V
2.9
IOH = − 50 mA
4.5 V
4.4
5.5 V
5.4
VOH
IOH = − 4 mA
IOH = − 24 mA
IOH = − 75 mA†
3 V 2.58
4.5 V 3.94
5.5 V 4.94
5.5 V
3V
0.1
IOL = 50 mA
4.5 V
0.1
5.5 V
0.1
VOL
IOL = 12 mA
IOL = 24 mA
3V
0.36
4.5 V
0.36
5.5 V
0.36
IOL = 75 mA†
5.5 V
IOZ
VO = VCC or GND
5.5 V
± 0.5
II
VI = VCC or GND
5.5 V
± 0.1
ICC
VI = VCC or GND, IO = 0
5.5 V
8
Ci
VI = VCC or GND
5V
4
Co
VO = VCC or GND
5V
10
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
MIN MAX UNIT
2.9
4.4
5.4
2.48
V
3.8
4.8
3.85
0.1
0.1
0.1
0.44 V
0.44
0.44
1.65
± 5 mA
± 1 mA
80 mA
pF
pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
2−3