English
Language : 

LM4F111B2QR Datasheet, PDF (230/1113 Pages) Texas Instruments – Microcontroller
System Control
Bit/Field
3
2
1
0
Name
MOFRIS
reserved
BORRIS
reserved
Type
RO
RO
RO
RO
Reset
0
0
0
0
Description
Main Oscillator Failure Raw Interrupt Status
Value Description
1 The MOSCIM bit in the MOSCCTL register is set and the main
oscillator has failed.
0 The main oscillator has not failed.
This bit is cleared by writing a 1 to the MOFMIS bit in the MISC register.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
Brown-Out Reset Raw Interrupt Status
Value Description
1 A brown-out condition is currently active.
0 A brown-out condition is not currently active.
Note the BORIOR bit in the PBORCTL register must be cleared to cause
an interrupt due to a Brown Out Event.
This bit is cleared by writing a 1 to the BORMIS bit in the MISC register.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
230
April 25, 2012
Texas Instruments-Advance Information