BQ40Z50-R2 Datasheet, PDF (23/51 Pages) Texas Instruments – 1-Series, 2-Series, 3-Series, and 4-Series Li-Ion Battery Pack Manager | |||
|
◁ |
www.ti.com
bq40z50-R2
SLUSCS4 â JUNE 2017
8.3 Feature Description
8.3.1 Primary (1st Level) Safety Features
The bq40z50-R2 supports a wide range of battery and system protection features that can easily be configured.
See the bq40z50-R2 Technical Reference Manual (SLUUBK0) for detailed descriptions of each protection
function.
The primary safety features include:
⢠Cell Overvoltage Protection
⢠Cell Undervoltage Protection
⢠Cell Undervoltage Protection Compensated
⢠Overcurrent in Charge Protection
⢠Overcurrent in Discharge Protection
⢠Overload in Discharge Protection
⢠Short Circuit in Charge Protection
⢠Short Circuit in Discharge Protection
⢠Overtemperature in Charge Protection
⢠Overtemperature in Discharge Protection
⢠Undertemperature in Charge Protection
⢠Undertemperature in Discharge Protection
⢠Overtemperature FET protection
⢠Precharge Timeout Protection
⢠Host Watchdog Timeout Protection
⢠Fast Charge Timeout Protection
⢠Overcharge Protection
⢠Overcharging Voltage Protection
⢠Overcharging Current Protection
⢠Over Precharge Current Protection
8.3.2 Secondary (2nd Level) Safety Features
The secondary safety features of the bq40z50-R2 can be used to indicate more serious faults via the FUSE pin.
This pin can be used to blow an in-line fuse to permanently disable the battery pack from charging or
discharging. See the bq40z50-R2 Technical Reference Manual (SLUUBK0) for detailed descriptions of each
protection function.
The secondary safety features provide protection against:
⢠Safety Overvoltage Permanent Failure
⢠Safety Undervoltage Permanent Failure
⢠Safety Overtemperature Permanent Failure
⢠Safety FET Overtemperature Permanent Failure
⢠Qmax Imbalance Permanent Failure
⢠Impedance Imbalance Permanent Failure
⢠Capacity Degradation Permanent Failure
⢠Cell Balancing Permanent Failure
⢠Fuse Failure Permanent Failure
⢠PTC Permanent Failure
⢠Voltage Imbalance At Rest Permanent Failure
⢠Voltage Imbalance Active Permanent Failure
⢠Charge FET Permanent Failure
⢠Discharge FET Permanent Failure
⢠AFE Register Permanent Failure
⢠AFE Communication Permanent Failure
Copyright © 2017, Texas Instruments Incorporated
Product Folder Links: bq40z50-R2
Submit Documentation Feedback
23
|
▷ |