BQ40Z50-R2 Datasheet, PDF (16/51 Pages) Texas Instruments – 1-Series, 2-Series, 3-Series, and 4-Series Li-Ion Battery Pack Manager | |||
|
◁ |
bq40z50-R2
SLUSCS4 â JUNE 2017
www.ti.com
7.31 OCD, SCC, SCD1, SCD2 Current Protection Thresholds
Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = â40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
VOCD
OCD detection
threshold voltage range
VOCD = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VOCD = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
â16.6
â8.3
â100
mV
â50
ÎVOCD
OCD detection
threshold voltage
program step
VOCD = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VOCD = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
â5.56
mV
â2.78
VSCC
SCC detection
threshold voltage range
VSCC = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCC = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
44.4
22.2
200
mV
100
ÎVSCC
SCC detection
threshold voltage
program step
VSCC = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCC = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
22.2
mV
11.1
VSCD1
SCD1 detection
threshold voltage range
VSCD1 = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCD1 = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
â44.4
â22.2
â200
mV
â100
ÎVSCD1
SCD1 detection
threshold voltage
program step
VSCD1 = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCD1 = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
â22.2
mV
â11.1
VSCD2
SCD2 detection
threshold voltage range
VSCD2 = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCD2 = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
â44.4
â22.2
â200
mV
â100
ÎVSCD2
SCD2 detection
threshold voltage
program step
VSCD2 = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 1
VSCD2 = VSRP â VSRN, AFE PROTECTION
CONTROL[RSNS] = 0
â22.2
mV
â11.1
VOFFSET
OCD, SCC, and SCDx
offset error
Post-trim
â2.5
2.5 mV
VSCALE
OCD, SCC, and SCDx No trim
scale error
Post-trim
â10%
â5%
10%
â
5%
7.32 Timing Requirements: OCD, SCC, SCD1, SCD2 Current Protection Timing
Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = â40°C to 85°C and VCC =
2.2 V to 26 V (unless otherwise noted)
MIN
NOM
MAX UNIT
tOCD
OCD detection
delay time
1
31 ms
ÎtOCD
OCD detection
delay time
program step
2
ms
tSCC
SCC detection
delay time
0
915
µs
ÎtSCC
SCC detection
delay time
program step
61
µs
tSCD1
SCD1 detection AFE PROTECTION CONTROL[SCDDx2] = 0
delay time
AFE PROTECTION CONTROL[SCDDx2] = 1
0
915
µs
0
1850
16
Submit Documentation Feedback
Product Folder Links: bq40z50-R2
Copyright © 2017, Texas Instruments Incorporated
|
▷ |