8.6.2.7 I2C Bus Sub-Address 1 to 3 (SUBADR1–SUBADR3) Register
Table 9. SUBADR1–SUBADR3 – I2C Bus Sub-Address Registers (Address 18h–1Ah) Bit Description
ADDRESS REGISTER BIT
SYMBOL
ACCESS (1)
VALUE (2)
DESCRIPTION
7:5
A1[7:5]
R
18h
SUBADR1 4:1
A1[4:1]
R/W
110
1001
I2C bus sub-address 1
0
A1[0]
R
0
7:5
A2[7:5]
R
19h
SUBADR2 4:1
A2[4:1]
R/W
110
1010
I2C bus sub-address 2
0
A2[0]
R
0
7:5
A3[7:5]
R
1Ah
SUBADR3 4:1
A31[4:1]
R/W
110
1100
I2C bus sub-address 3
0
A3[0]
R
0
(1) R = read, W = write
(2) Default value
Sub-addresses are programmable through the I2C bus. Default power-up values are D2h, D4h, D8h and the
device(s) will not acknowledge these addresses right after power-up (the corresponding SUBx bit in MODE1
register is equal to 0).
Once sub-addresses have been programmed to their right values, SUBx bits need to be set to 1 in order to have
the device acknowledging these addresses (MODE1 register).
Only the 7 MSBs representing the I2C bus sub-address are valid. The LSB in SUBADRx register is a read-only
bit (0).
When SUBx is set to 1, the corresponding I2C bus sub-address can be used during either an I2C-bus read or
write sequence.
8.6.2.8 LED All-Call I2C Bus Address (ALLCALLADR) Register
Table 10. ALLCALLADR – All-Call I2C Bus Address Register (Address 1Bh) Bit Description
ADDRESS REGISTER BIT
SYMBOL
ACCESS (1)
VALUE (2)
DESCRIPTION
7:5
AC[7:5]
R
1Bh
ALLCALLA
DR
4:1
AC[4:1]
R/W
0
AC[0]
R
110
1000
0
ALLCALLADR I2C bus address register
(1) R = read, W = write
(2) Default value
The LED All Call I2C bus address allows all the TLC59116Fs in the bus to be programmed at the same time
(ALLCALL bit I2C-bus read or write sequence in register MODE1 must be equal to 1 (power-up default state)).
This address is programmable through the I2C bus and can be used during either an I2C-bus read or write
sequence. The register address can also be programmed as a Sub Call.
Only the 7 MSBs representing the All Call I2C bus address are valid. The LSB in ALLCALLADR register is a
read-only bit (0).
If ALLCALL bit = 0 (MODE1), the device does not acknowledge the address programmed in register