Looking at the state diagram, one can see that the CONV
pattern needed to generate a given state progression is not
unique. Upon entering states 1 or 8, the DDC118 remains
in those states until mbsy goes low, independent of CONV.
As long as the m/r/az cycle is underway, the state machine
ignores CONV (see Figure 10, page 14). The top two
signals in Figure 16 are different CONV patterns that
produce the same state. This feature allows flexibility in
generating ncont mode CONV patterns. For example, the
DDC118 Evaluation Fixture operates in the ncont mode by
generating a square wave with pulse width < t6. Figure 17
illustrates operation in the ncont mode using a 50% duty
SBAS325B − JUNE 2004 − REVISED APRIL 2009
cycle CONV signal with TINT = 512 CLK periods. Care
must be exercised when using a square wave to generate
CONV. There are certain integration times that must be
avoided since they produce very short intervals for state 2
(or state 7 if CONV is inverted). As seen in the state
diagram, the state progresses from 2 to 3 as soon as
CONV is high. The state machine does not insure that the
duration of state 2 is long enough to properly prepare the
next side for integration (t11). This must be done by the
user with proper timing of CONV. For example, if CONV is
a square wave with TINT = 970 CLK periods, state 2 will
only be 9 CLK periods long; therefore, t11 will not be met.
CONV1
CONV2
mbsy
State
3
4
1
23
4
1
2
Figure 16. Equivalent CONV Signals in Non-Continuous Mode
CONV
State
3
4
1
Integration
Status
mbsy
Int A Int B
2
3
4
1
Int A Int B
DVALID
Side A
Data
Side B
Data
Side A
Data
Figure 17. Non-Continuous Mode Timing with a 50% Duty Cycle CONV Signal
19