English
Language : 

BQ2970 Datasheet, PDF (19/31 Pages) Texas Instruments – Cost-Effective Voltage and Current Protection Integrated Circuit
www.ti.com
Device Functional Modes (continued)
bq2970, bq2971, bq2972, bq2973
SLUSBU9C – MARCH 2014 – REVISED MARCH 2016
CAUTION
Some battery providers do not recommend charging a depleted (self-discharged)
battery. Consult the battery supplier to determine whether to enable or inhibit the 0-V
battery charger function.
9.4.8 Delay Circuit
The detection delay timers are based from an internal clock with a frequency of 10 kHz.
BAT
VSS
tD 0 ≤ tD ≤ tSCCD
Time
VSCC
tD ˂ tOCDD
VOCD
VSS
Time
Figure 25. Delay Circuit
If the over-discharge current is detected, but remains below the over-discharge short circuit detection threshold,
the over-discharge detection conditions must be valid for a time greater than or equal to over-discharge current
delay tOCCD time before the DOUT goes low to turn OFF the discharge FET. However, during any time the
discharge overcurrent detection exceeds the short circuit detection threshold for a time greater than or equal to
load circuit detection delay tSCCD, the DOUT pin goes low in a faster delay for protection.
Copyright © 2014–2016, Texas Instruments Incorporated
Submit Documentation Feedback
19
Product Folder Links: bq2970 bq2971 bq2972 bq2973