8.7 Turn-On and Turn-Off Time
Turn-on time is defined as the time taken by the output of the MUX36xxx to rise to 90% of the final value after
the enable signal has risen to 50% of its final value. Figure 31 shows the setup used to measure turn-on time.
Turn-on time is denoted by the symbol tON.
Turn off time is defined as the time taken by the output of the MUX36xxx to fall to 10% of the initial value after
the enable signal has fallen to 50% of its initial value. Figure 31 shows the setup used to measure turn-off time.
Turn-off time is denoted by the symbol tOFF.
VDD
VSS
3V
Enable
Drive (VIN)
0V
50%
50%
VDD
VSS
A0
S1
VS
A1
S2-S8
A2
tON (EN)
Output
0.9 VS
tOFF (EN)
0.1 VS
VIN
MUX36S08
Output
EN
D
GND
300 Ÿ
35 pF
Figure 31. Turn-On and Turn-Off Time Measurement Setup