English
Language : 

BQ28Z560-R1_14 Datasheet, PDF (15/61 Pages) Texas Instruments – Single Cell Li-Ion Battery Gas Gauge
Not Recommended For New Designs
bq28z560-R1
www.ti.com
SLUSBD3 – APRIL 2013
Additionally, if the voltage across both protection MOSFETs (VM – VSS) becomes higher than the short-circuit
voltage (VSHORT = VBAT – 0.9 V typ) for a period up to the discharge short-circuit detection delay time
(tSHORT = 400 µs typ), the bq28z560-R1 detects short-circuit of the battery and the DOUT pin transitions to a low
level. This prohibits discharging the battery by turning off the external discharge control N-channel MOSFET.
In both the discharge overcurrent and short-circuit states, an internal discharge overcurrent release resistor (20
kΩ typ) is turned on (switched in between VM and VSS), allowing the VM pin to be pulled down to the VSS
potential if the load is released. If the VM – VSS voltage becomes lower than the discharge overcurrent detection
voltage (VDET3 = 0.150 V typ) for a period up to the discharge overcurrent release delay time (tREL3 = 4 ms typ),
the discharge overcurrent release resistor is turned off and the DOUT pin transitions to a high level, enabling
discharge of the battery by turning on the external discharge control N-channel MOSFET.
Normal
Discharge
Overcurrent
Normal
Discharge
Overcurrent
Normal
VDET1
VREL1
VDET2
BAT
VSS
BAT
VSS
PACK–
BAT
VSHORT
VDET3
VSS
tOCD
Load
Connected
tOCR
Load
Disconnected
tSHORT
Load Short
Circuit
tOCR
Copyright © 2013, Texas Instruments Incorporated
Product Folder Links: bq28z560-R1
Submit Documentation Feedback
15