English
Language : 

CC2640R2F-Q1 Datasheet, PDF (14/40 Pages) Texas Instruments – SimpleLink Bluetooth low energy Wireless MCU for Automotive
CC2640R2F-Q1
SWRS201 – JANUARY 2017
www.ti.com
ADC Characteristics (continued)
Tc = 25°C, VDDS = 3.0 V and voltage scaling enabled, unless otherwise noted.(1)
PARAMETER
TEST CONDITIONS
Conversion time
Serial conversion, time-to-output, 24-MHz clock
Current consumption
Current consumption
Reference voltage
Reference voltage
Reference voltage
Reference voltage
Input Impedance
Internal 4.3-V equivalent reference(2)
VDDS as reference
Equivalent fixed internal reference (input voltage scaling
enabled). For best accuracy, the ADC conversion should
be initiated through the TI-RTOS API to include the
gain/offset compensation factors stored in FCFG1.
Fixed internal reference (input-voltage scaling disabled).
For the best accuracy, the ADC conversion should be
initiated through the TI-RTOS API to include the gain/offset
compensation factors stored in FCFG1. This value is
derived from the scaled value (4.3 V) as follows.
Vref = 4.3 V × 1408 / 4095
VDDS as reference (also known as RELATIVE) (input
voltage scaling enabled)
VDDS as reference (also known as RELATIVE) (input
voltage scaling disabled)
200 ksps, voltage scaling enabled. Capacitive input, input
impedance depends on sampling frequency and sampling
time
(5) Applied voltage must be within absolute maximum ratings at all times (see Section 5.1).
MIN
TYP
50
0.66
0.75
4.3 (2) (5)
1.48
VDDS
VDDS /
2.82 (5)
>1
MAX
UNIT
clock-
cycles
mA
mA
V
V
V
V
MΩ
5.13 Temperature Sensor
Measured on the TI CC2640Q1EM-7ID reference design with Tc = 25°C, VDDS = 3.0 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN TYP MAX
Resolution
4
Range
–40
105
Accuracy
±5
Supply voltage coefficient(1)
3.2
(1) Automatically compensated when using supplied driver libraries.
UNIT
°C
°C
°C
°C/V
5.14 Battery Monitor
Measured on the TI CC2640Q1EM-7ID reference design with Tc = 25°C, VDDS = 3.0 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN TYP MAX
Resolution
50
Range
1.8
3.8
Accuracy
13
UNIT
mV
V
mV
5.15 Continuous Time Comparator
Tc = 25°C, VDDS = 3.0 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
Input voltage range
External reference voltage
Internal reference voltage
DCOUPL as reference
Offset
Hysteresis
Decision time
Current consumption when enabled(1)
Step from –10 mV to 10 mV
(1) Additionally, the bias module must be enabled when running in standby mode.
MIN TYP MAX
0
VDDS
0
VDDS
1.27
3
<2
0.72
8.6
UNIT
V
V
V
mV
mV
µs
µA
14
Specifications
Submit Documentation Feedback
Product Folder Links: CC2640R2F-Q1
Copyright © 2017, Texas Instruments Incorporated