BQ29330 Datasheet, PDF (8/26 Pages) Texas Instruments – 2-,3-,AND 4-CELL LITHIUM-ION OR LITHIUM-POLYMER BATTERY PROTECTION AFE | |||
|
◁ |
bq29330
SLUS673A â SEPTEMBER 2005 â REVISED DECEMBER 2005
www.ti.com
ELECTRICAL CHARACTERISTICS (Continued)
CELL VOLTAGE MONITOR, TA = 25°C, CREG = 1 µF, CL = 2.2 µF, VCC or BAT = 14 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
V(CELLOUT)
REF
PACK
CELL output
VCnâ VCn+1 = 0 V, 8 V ⤠VDD ⤠25 V
VCnâ VCn+1 = 4.5 V, 8 V ⤠VDD ⤠25 V
Mode (1), 8 V ⤠VDD ⤠25 V
Mode
[Register Address = 0x03, b1(PACK) = 1, b0( VMEN) = 1]
0.950
0.275
â1%
â2%
BAT
Mode
[Register Address = 0X03, b6(BAT) = 1, b0 ( VMEN) = 1]
â2%
CMRR
Common mode rejection
CELL max to CELL min
40
V(CELLSLEW)
CELL output rise
K
CELL scale factor
Min to Max 10% to 90%
K = {CELL output (VC5 = 0 V, VC4 = 4.5 V)
â CELL output (VC5 = VC4 = 0 V)} / 4.5
K = {CELL output (VC2 = 13.5 V, VC1 = 18 V)
â CELL output (VC2 = VC1 = 13.5 V)} / 4.5
9
0.147
0.147
I(VCELLOUT)
Drive current
VCnâ VCn+1 = 0 V , Vcell = 0 V, TA = â40° to 110°
12
VICR
CELL output offset error
CELL output (VC2 = 18 V, VC1 = 18 V)
âCELL output (VC2 = VC1 = 0 V)
R(BAL)
Cell balance internal resistance RDS(ON) for internal FET switch at VDS = 2 V
â50%
TYP
0.975
0.3
0.975
PACK/18
MAX
1
0.325
1%
2%
BAT/18
2%
0.150 0.153
0.150
18
â1
400
0.153
50%
UNIT
V
V
V
V
dB
ms
µA
mV
â¦
(1) Register Address = 0x04, b2(CAL0) = b3(CAL1) = 1, Register Address = 0x03, b0(VMEN) = 1
CURRENT PROTECTION DETECTION, TA = 25°C, CREG = 1 µF, CL = 2.2 µF, VCC or BAT = 14 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP
RSNS = 0
50
V(OLT)
OL detection threshold voltage range, typical(1)
RSNS = 1
25
RSNS = 0
5
âV(OLT)
OL detection threshold voltage program step
RSNS = 1
2.5
V(SCCT)
âV(SCCT)
SCC detection threshold voltage range, typical
(2)
SCC detection threshold voltage program step
RSNS = 0
RSNS = 1
RSNS = 0
RSNS = 1
RSNS is set in
FUNCTION_CTL register
100
50
25
12.5
V(SCDT)
SCD detection threshold voltage range,
typical (3)
RSNS = 0
RSNS = 1
â100
â50
âV(SCDT)
RSNS = 0
SCD detection threshold voltage program step
RSNS = 1
â25
â12.5
VOL(acr)
OL detection threshold voltage accuracy(1)
V(SCC_acr) SCC detection threshold voltage accuracy(2)
V(SCD_acr) SCD detection threshold voltage accuracy(3)
VOL = 25 mV (min)
VOL = 100 mV (RSNS = 0,1)
VOL = 205 mV (max)
VSCC = 50 mV (min)
VSCC = 200 mV (RSNS = 0,1)
VSCC = 475 mV (max)
VSCC = â50 mV (min)
VSCC = â200 mV (RSNS = 0,1)
VSCC = â475 mV (max)
15
90
185
â30
â180
â428
30
180
426
25
100
205
â50
â200
â475
50
200
475
MAX
205
102.5
475
237.5
â475
â237.5
35
110
225
70
â220
â523
70
220
523
UNIT
mV
mV
mV
mV
mV
mV
mV
mV
mV
(1) See OLV register for setting detection threshold
(2) See SCC register for setting detection threshold
(3) See SCD register for setting detection threshold
8
|
▷ |