ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)(1)(2)
Supply voltage range (VCC, BAT)
(VC1, VC2, VC3, VC4, PACK, PMS)
(VC5)
Input voltage range
(SRP, SRN)
(VC1 to VC2, VC2 to VC3, VC3 to VC4, VC4
to VC5)
(WDI, SCLK, SDATA)
(DSG,CHG)
(ZVCHG)
Output voltage range
(GPOD)
(TOUT, SDATA, CELL, XALERT, XRST,
LEDOUT)
(CELL+)
Current for cell balancing
Storage temperature range, Tstg
Lead temperature (soldering, 10 s)
bq29330
–0.3 to 34
–0.3 to 34
–0.3 to 1.0
–1.0 to 1.0
–0.3 to 8.5
– 0.3 to 8.5
–0.3 to BAT
–0.3 to 34
–0.3 to 34
–0.3 to 7
–0.3 to 7
10
–65 to 150
300
UNIT
V
mA
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground of this device except VCn-VC(n+1), where n=1, 2, 3, 4 cell voltage.
RECOMMENDED OPERATING CONDITIONS
Supply voltage ( VCC,BAT)
VI(STARTUP) Start up voltage (VCC,BAT)
VI
Input voltage range
VIH
Logic level input voltage
VIL
VO
Output voltage
VO
Output voltage range
External 2.5V REG capacitor
External LEDOUT capacitor
Extend CELL output capacitor
IOL
RPACK
Input frequency
WDI high time
Operating temperature
TA
Functional temperature
VC1, VC2, VC3, VC4
VC5
SRP, SRN
VCn – VC(n+1), (n=1, 2, 3, 4 )
PACK, PMS
SCLK, SDATA, WDI
GPOD
XALERT, SDATA, XRST
CELL+, CELL–
CREG
CLED
CCELL
GPOD
WDI
MIN
4.5
5.5
0
0
–0.5
0
0.8×REG
0
1.0
2.2
2
–25
–40
NOM
MAX
25
0.975
VDD
0.5
0.5
5.0
25
REG
0.2×REG
25
REG
0.1
1
1
32.768
85
110
UNIT
V
V
V
V
V
V
µF
µF
µF
mA
kΩ
kHz
µs
°C
°C
6