Recommended Operating Conditions (continued)
NAME
DESCRIPTION
CONDITION
MIN
Differential
Clock Input
Voltage
Differential input voltage, SATA_REFCLKP and
SATA_REFCLKN
250
Transition
Time
tt
Transition time, 10%-90%, All Inputs (unless otherwise
specified in the electrical data sections)
Operating
Frequency
FPLL0_SYSCLK1,6
Military temperature grade
(M suffix)
CVDD = 1.2V
operating point
0
NOM
MAX
2000
UNIT
mV
0.25P or 10 (5)
345 (6)
ns
MHz
(5) Whichever is smaller. P = the period of the applied signal. Maintaining transition times as fast as possible is recommended to improve
noise immunity on input signals.
(6) This operating point is 300 MHz on revision 1.x silicon.
Copyright © 2011–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: OMAPL138B-EP
Device Operating Conditions