electrical characteristics over recommended operating free-air temperature range, VCC = 15 V (see
Note 4), RT = 10 kΩ, CT = 3.3 nF (unless otherwise specified) (continued)
supply voltage
PARAMETER
TEST CONDITIONS
TL284x
MIN TYP† MAX
TL384x
MIN TYP† MAX UNIT
Start-up current
0.5
1
0.5
1 mA
Operating supply current
VFB and ISENSE at 0 V
11
17
11
17 mA
Limiting voltage
ICC = 25 mA
34
† All typical values are at TA = 25°C.
NOTE 4: Adjust VCC above the start threshold before setting it to 15 V.
34
V