English
Language : 

TL284X_07 Datasheet, PDF (6/18 Pages) Texas Instruments – CURRENT-MODE PWM CONTROLLERS
TL284x, TL384x
CURRENT-MODE PWM CONTROLLERS
SLVS038F – JANUARY 1989 – REVISED FEBRUARY 2003
electrical characteristics over recommended operating free-air temperature range, VCC = 15 V (see
Note 4), RT = 10 kΩ, CT = 3.3 nF (unless otherwise specified) (continued)
current-sense section
PARAMETER
TEST CONDITIONS
TL284x
MIN TYP† MAX
TL384x
MIN TYP†
Voltage amplification
See Notes 6 and 7
2.85
3 3.13 2.85
3
Current-sense comparator threshold COMP at 5 V,
See Note 6
0.9
1 1.1 0.9
1
Supply-voltage rejection ratio
Input bias current
VCC = 12 V to 25 V, See Note 6
70
70
–2 –10
–2
Delay time to output
150 300
150
† All typical values are at TA = 25°C.
NOTES: 4. Adjust VCC above the start threshold before setting it to 15 V.
6. These parameters are measured at the trip point of the latch, with VFB at 0 V.
7. Voltage amplification is measured between ISENSE and COMP, with the input changing from 0 V to 0.8 V.
MAX
3.15
1.1
–10
300
UNIT
V/V
V
dB
µA
ns
output section
PARAMETER
TEST CONDITIONS
High-level output voltage
IOH = –20 mA
IOH = –200 mA
Low-level output voltage
IOL = 20 mA
IOL = 200 mA
Rise time
CL = 1 nF,
TA = 25°C
Fall time
CL = 1 nF,
TA = 25°C
† All typical values are at TA = 25°C.
NOTE 4: Adjust VCC above the start threshold before setting it to 15 V.
undervoltage-lockout section
TL284x
MIN TYP†
13 13.5
12 13.5
0.1
1.5
50
50
MAX
0.4
2.2
150
150
TL384x
MIN TYP†
13 13.5
12 13.5
0.1
1.5
50
50
MAX
0.4
2.2
150
150
UNIT
V
V
ns
ns
PARAMETER
Start threshold voltage
TLx842, TLx844
TLx843, TLx845
Minimum operating voltage after startup
TLx842, TLx844
TLx843, TLx845
† All typical values are at TA = 25°C.
NOTE 4: Adjust VCC above the start threshold before setting it to 15 V.
pulse-width-modulator section
TL284x
MIN TYP†
15
16
7.8 8.4
9
10
7 7.6
MAX
17
9
11
8.2
TL384x
MIN TYP†
14.5
16
7.8 8.4
8.5
10
7 7.6
MAX
17.5
9
11.5
8.2
UNIT
V
V
PARAMETER
Maximum duty cycle
TLx842, TLx843
TLx844, TLx845
Minimum duty cycle
† All typical values are at TA = 25°C.
NOTE 4: Adjust VCC above the start threshold before setting it to 15 V.
TL284x
MIN TYP†
95
97
46
48
MAX
100
50
0
TL384x
MIN TYP†
95
97
46
48
MAX
100
50
0
UNIT
%
6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265