English
Language : 

TL284X_07 Datasheet, PDF (5/18 Pages) Texas Instruments – CURRENT-MODE PWM CONTROLLERS
TL284x, TL384x
CURRENT-MODE PWM CONTROLLERS
SLVS038F – JANUARY 1989 – REVISED FEBRUARY 2003
electrical characteristics over recommended operating free-air temperature range, VCC = 15 V (see
Note 4), RT = 10 kΩ, CT = 3.3 nF (unless otherwise specified)
reference section
PARAMETER
TEST CONDITIONS
Output voltage
Line regulation
Load regulation
Temperature coefficient
of output voltage
IO = 1 mA,
VCC = 12 V to 25 V
IO = 1 mA to 20 mA
TA = 25°C
Output voltage
with worst-case variation
VCC = 12 V to 25 V, IO = 1 mA to 20 mA
Output noise voltage
f = 10 Hz to 10 kHz, TA = 25°C
Output-voltage long-term drift After 1000 h at TA = 25°C
Short-circuit output current
† All typical values are at TA = 25°C.
NOTE 4: Adjust VCC above the start threshold before setting it to 15 V.
oscillator section
TL284x
MIN TYP†
4.95
5
6
6
MAX
5.05
20
25
0.2 0.4
TL384x
MIN TYP†
4.9
5
6
6
MAX
5.1
20
25
UNIT
V
mV
mV
0.2 0.4 mV/°C
4.9
5.1 4.82
5.18 V
50
50
µV
5
25
5
25 mV
–30 –100 –180 –30 –100 –180 mA
PARAMETER
TEST CONDITIONS
TL284x
MIN TYP† MAX
TL384x
MIN TYP† MAX UNIT
Oscillator frequency (see Note 5)
Frequency change with supply voltage
Frequency change with temperature
TA = 25°C
VCC = 12 V to 25 V
47
52
57
47
52
57 kHz
2
10
2
10 Hz/kHz
50
50
Hz/kHz
Peak-to-peak amplitude at RT/CT
1.7
1.7
V
† All typical values are at TA = 25°C.
NOTES: 4. Adjust VCC above the start threshold before setting it to 15 V.
5. Output frequency equals oscillator frequency for the TLx842 and TLx843. Output frequency is one-half the oscillator frequency for
the TLx844 and TLx845.
error-amplifier section
PARAMETER
TEST CONDITIONS
Feedback input voltage
COMP at 2.5 V
Input bias current
Open-loop voltage amplification
Gain-bandwidth product
VO = 2 V to 4 V
Supply-voltage rejection ratio
Output sink current
VCC = 12 V to 25 V
VFB at 2.7 V, COMP at 1.1 V
Output source current
VFB at 2.3 V, COMP at 5 V
High-level output voltage
VFB at 2.3 V, RL = 15 kΩ to GND
Low-level output voltage
VFB at 2.7 V, RL = 15 kΩ to GND
† All typical values are at TA = 25°C.
NOTE 4: Adjust VCC above the start threshold before setting it to 15 V.
TL284x
MIN TYP†
2.45 2.50
–0.3
65
90
0.7
1
60
70
2
6
–0.5 –0.8
5
6
0.7
MAX
2.55
–1
1.1
TL384x
MIN TYP†
2.42 2.50
–0.3
65
90
0.7
1
60
70
2
6
–0.5 –0.8
5
6
0.7
MAX
2.58
–2
1.1
UNIT
V
µA
dB
MHz
dB
mA
mA
V
V
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5